Biomedical Engineering for A Better Life

نویسنده

  • Mitra Djamal
چکیده

This special issue contains a selection of interesting contribution from academia. Partly of the articles that have been presented in the In the first article, Biosensor Based on Giant Magnetoresistance Material, Djamal et al. demonstrate a comprehensive review on novel approach in biosensor based on GMR material. Compared with the traditional optical detection that widely used in biomedicine, GMR sensors are more sensitive, portable and give a fully electronic readout. In addition, GMR sensor is inexpensive and the fabrication is compatible with the current VLSI (Very Large Scale Integration) technology, so GMR sensors can be easily integrated with electronics and microfluidics to detect many different analytes on a single chip. In the second article, Non-Compactness Attribute Filtering to Extract Retinal Blood Vessels in Fundus Images, I. K. E. Purnama et al. propose a new method consisting of a sequence of procedures to segment blood vessels in a retinal image. In the method, attribute filtering with a so-called Max-Tree is used to represent the image based on its gray value. The filtering process is done using the branches filtering approach in which the tree branches are selected based on the non-compactness of the nodes. The selection is started from the leaves. This experiment was done to 40 retinal images, and utilizes the manual segmentation created by an observer to validate the results. The proposed method can deliver the average accuracy of 94.21%. The third article, An Improved Olympic Hole-Filling Method for Ultrasound Volume Reconstruction of Human Spine, Dewi et al. propose an improved Olympic operator for Hole-filling algorithm, and apply it to generate the volume in freehand 3D ultrasound reconstruction of the spine. The conventional Olympic operator defines the empty voxels by sorting the neighboring voxels, removing the n% of the upper and lower values, and averaging them to attain the value to fill the empty voxels. The empty voxel estimation can be improved by thresholding the range width of its neighboring voxels and adjusting it to the average values. The method is tested on a hole-manipulated volume derived from a cropped 3D ultrasound volume of a part of the spine. The proposed technique shows improved result compared to all tested existing methods.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

P81: Detection of Epileptic Seizures Using EEG Signal Processing

Epilepsy is the most common brain diseases that cause many problems in the daily life of the patient. In most attempts to automatic detection, the attack used an EEG. In this paper, The complete data set consists of five sets recorded from normal and epileptic patients. Each set containing 100 single-channel EEG segments. Here we used first and last sets (A and E). Set A consisted of segments r...

متن کامل

Electrochemical miRNA Biosensors: The Benefits of Nanotechnology

The importance of nanotechnology in medical technologies, especially biomedical diagnostics, is indubitable. By taking advantages of nanomaterials, many medical diagnostics methods have been developed so far, including electrochemical nanobiosensors. They have been used for quantification of different clinical biomarkers for detecting, screening, or follow up a disease. microRNAs (miRNAs) are o...

متن کامل

Genetic Feedforward-Feedback Controller for Functional Electrical Stimulation Control of Elbow Joint Angle

Background: Functional electrical stimulation (FES) is the most commonly used system for restoring functions after spinal cord injury (SCI). Objective: In this study we investigated feedback PID and feedforward-feedback P-PID controllers for regulating the elbow joint angle. Methods: The controllers were tuned based on a nonlinear muculoskeletal model containing two links, one joint with one de...

متن کامل

Effect of Coating Materials on the Fatigue Behavior of Hip Implants: A Three-dimensional Finite Element Analysis

This study aims to validate, using finite element analysis (FEA), the design concept by comparing the fatigue behavior of hip implant stems coated with composite (carbon/PEEK) and polymeric (PEEK) coating materials corresponding to different human activities: standing up, normal walking and climbing stairs under dynamic loadings to find out which of all these models have a better performance in...

متن کامل

Fabrication of Porous Segments Using Ti-6Al-4V Chips for Orthopaedic Applications

Different methods have been evaluated for manufacturing the porous Ti6Al4V alloys according to decreasing stress shielding phenomenon and increasing mechanical compatibility between the metallic components and the host tissue. For this purpose, in this work Ti6Al4V alloy chips were pressed under 400 MPa pressure and then samples were categorized and heated into two groups at 1000 and 1150℃ unde...

متن کامل

Studying the Mechanical Behavior of Tissue in the Generation of Pressure Sores using Simulation and a Guinea Pig Experimental Model

Introduction:  Pressure  sores  refer  to  lesions  that  are  produced  while  a  constant  pressure  causes  necrotic  tissue to grow. The need for a better comprehension of the process has led researchers to artificial generation  of  pressure  sores.  Modeling  the  mechanical  behavior  of tissue  will  provide  a better understanding  of this  process as well as a more suitable selection ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010