Electrical impedance tomography and trans-pulmonary pressure measurements in a patient with extreme respiratory drive

نویسندگان

  • Atsuko Shono
  • Peter Somhorst
  • Diederik Gommers
چکیده

Preserving spontaneous breathing during mechanical ventilation prevents muscle atrophy of the diaphragm, but may lead to ventilator induced lung injury (VILI). We present a case in which monitoring of trans-pulmonary pressure and ventilation distribution using Electrical Impedance Tomography (EIT) provided essential information for preventing VILI.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Use of thoracic electrical impedance tomography as an auxiliary tool for alveolar recruitment maneuvers in acute respiratory distress syndrome: case report and brief literature review

Thoracic electrical impedance tomography is a real-time, noninvasive monitoring tool of the regional pulmonary ventilation distribution. Its bedside use in patients with acute respiratory distress syndrome has the potential to aid in alveolar recruitment maneuvers, which are often necessary in cases of refractory hypoxemia. In this case report, we describe the monitoring results and interpretat...

متن کامل

Serial changes in nasal potential difference and lung electrical impedance tomography at high altitude.

Recent work suggests that treatment with inhaled beta(2)-agonists reduces the incidence of high-altitude pulmonary edema in susceptible subjects by increasing respiratory epithelial sodium transport. We estimated respiratory epithelial ion transport by transepithelial nasal potential difference (NPD) measurements in 20 normal male subjects before, during, and after a stay at 3,800 m. NPD hyperp...

متن کامل

Electrical Impedance Tomography-guided PEEP Titration in Patients Undergoing Laparoscopic Abdominal Surgery

The aim of the study is to utilize electrical impedance tomography (EIT) to guide positive end-expiratory pressure (PEEP) and to optimize oxygenation in patients undergoing laparoscopic abdominal surgery.Fifty patients were randomly assigned to the control (C) group and the EIT (E) group (n = 25 each). We set the fraction of inspired oxygen (FiO2) at 0.30. The PEEP was titrated and increased in...

متن کامل

Special Section on the 2011 IEEE International Symposium on Medical Measurements and Applications

Using Alternating Kalman Filtering to Analyze Oscillometric Blood Pressure Waveforms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . J. A. de la O Serna, W. Van Moer, and K. Barbé 2621 A Combined Wavelet-Based Mesh-Free Method fo...

متن کامل

A Novel Resistive Capacitive Feedback Trans-impedance Amplifier Optimization Using IPSO Algorithm

A novel low noise trans-impedance amplifier is proposed using low cost 0.18 µm CMOS technology. A resistive-capacitive feedback is used to extend the bandwidth of the amplifier. As the structure is inductor less, it is suitable for low cost integrated optical interconnects. In this paper Improved Particle Swarm Optimization have applied to determine optimal trans-resistance and noise of propose...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 20  شماره 

صفحات  -

تاریخ انتشار 2017