Validation and uncertainty analysis of a pre-treatment 2D dose prediction model.

نویسندگان

  • Jose A Baeza
  • Cecile J A Wolfs
  • Sebastiaan M J J G Nijsten
  • Frank Verhaegen
چکیده

Independent verification of complex treatment delivery with megavolt photon beam radiotherapy (RT) has been effectively used to detect and prevent errors. This work presents the validation and uncertainty analysis of a model that predicts 2D portal dose images (PDIs) without a patient or phantom in the beam. The prediction model is based on an exponential point dose model with separable primary and secondary photon fluence components. The model includes a scatter kernel, off-axis ratio map, transmission values and penumbra kernels for beam-delimiting components. These parameters were derived through a model fitting procedure supplied with point dose and dose profile measurements of radiation fields. The model was validated against a treatment planning system (TPS; Eclipse) and radiochromic film measurements for complex clinical scenarios, including volumetric modulated arc therapy (VMAT). Confidence limits on fitted model parameters were calculated based on simulated measurements. A sensitivity analysis was performed to evaluate the effect of the parameter uncertainties on the model output. For the maximum uncertainty, the maximum deviating measurement sets were propagated through the fitting procedure and the model. The overall uncertainty was assessed using all simulated measurements. The validation of the prediction model against the TPS and the film showed a good agreement, with on average 90.8% and 90.5% of pixels passing a (2%,2 mm) global gamma analysis respectively, with a low dose threshold of 10%. The maximum and overall uncertainty of the model is dependent on the type of clinical plan used as input. The results can be used to study the robustness of the model. A model for predicting accurate 2D pre-treatment PDIs in complex RT scenarios can be used clinically and its uncertainties can be taken into account.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A statistical model for prediction of radiation induced sensorineural hearing loss in radiotherapy of brain

Introduction: The purpose of this study was to develop a statistical model for prediction of radiation induced sensorineural hearing loss (SNHL) induced by radiotherapy in patients with brain tumors.   Materials and Methods: CT scan of 18 patients (10 males and 8 females) with brain tumor who were referred to Radiation Center of Milad Hospital in Isfahan in 2...

متن کامل

Evaluation of a fast method of EPID-based dosimetry for IMRT and Comparison with 3D EPID-based dosimetry system using conventional two- and three-dimensional detectors for VMAT

Introduction: Electronic portal imaging devices (EPIDs) could potentially be useful for intensity-modulated radiation therapy (IMRT) and VMAT QA. The data density, high resolution, large active area, and efficiency of the MV EPID make it an attractive option. However, EPIDs were designed as imaging devices, not dosimeters, and as a result they do not inherently measure dose in ...

متن کامل

Using SWAT and SWAT-CUP for hydrological simulation and uncertainty analysis in arid and semi-arid watersheds (Case study: Zoshk Watershed, Shandiz, Iran)

The aims of this project was to assess the capability of SWAT model and SWAT-CUP software in hydrological simulation and to evaluate the uncertainty of SWAT model in estimating runoff in arid and semi-arid watersheds. Model calibration and uncertainty analysis were performed using the Sequential Uncertainty Fitting (SUFI2) algorithm. In the stage of calibration and validation of water flow, per...

متن کامل

Assessment of a 2D EPID-based Dosimetry Algorithm for Pre-treatment and In-vivo Midplane Dose Verification

Introduction: The use of electronic portal imaging devices (EPIDs) is a method for the dosimetric verification of radiotherapy plans both pretreatment and in-vivo. The aim of this study was to test a 2D EPID-based dosimetry algorithm for dose verification of some plans inside a homogenous and anthropomorphic phantom and in-vivo, as well. Materials and Methods: </strong...

متن کامل

Normal Tissue Complication Probability (NTCP) modeling and validation of quantitative analysis of normal tissue effects in the clinic (QUANTEC) guideline using quality of life questionnaire for parotid gland during head and neck radiotherapy

Introduction: Radiation therapy is the main treatment method for head and neck cancers, which comprise 3–5% of all cancers. A major side effect of this treatment is complication of the parotid glands, i.e. xerostomia, which occurs at relatively low doses. This complication leads to mouth dryness which is the most common problem for head and neck cancer survivors. There are dif...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 63 3  شماره 

صفحات  -

تاریخ انتشار 2018