Study on X-ray Spectra of Obscured AGNs based on Monte Carlo simulation - an interpretation of observed wide-band spectra

نویسندگان

  • Shinya Ikeda
  • Yuichi Terashima
چکیده

Monte Carlo simulation is one of the best tools to study the complex spectra of Compton-thick AGNs and to figure out the relation between their nuclear structures and X-ray spectra. We have simulated X-ray spectra of Comptonthick AGNs obscured by an accretion torus whose structure is characterized by a half-opening angle, an inclination angle of the torus relative to the observer, and a column density along the equatorial plane. We divided the simulated spectra into three components: one direct component, an absorbed reflection component and an unabsorbed reflection component. We then deduced the dependencies of these components on the parameters describing the structure of the torus. Our simulation results were applied to fit the wide-band spectrum of the Seyfert 2 galaxy Mrk 3 obtained by Suzaku. The spectral analysis indicates that we observe the nucleus along a line of sight intercepting the torus near its edge, and the column density along the equatorial plane was estimated to be ∼10 cm. Using this model, we can estimate the luminosities of both the direct emission and the emission irradiating the surrounding matter. This is useful to find the time variability and time lag between the direct and reflected light. Subject headings: galaxies: active — galaxies: Seyfert — radiative transfer — X-rays: individual (Mrk3)

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

X-ray spectra calculation for different target-filter of mammograms using MCNP Code

 ABSTRACTBackground: An electron beam generated X-ray spectrum consists of characteristic X-ray and continuous bermsstrahlung. The aim of this research is calculating and comparing X-ray spectra for different target filter of mammograms. Materials and Methods: Monte Carlo is a very powerful tool to simulate a series of different target-filter assembly in order to calculate the X-ray spectra. MC...

متن کامل

Calculation of Absorbed Glandular Dose using a FORTRAN Program Based on Monte Carlo X-ray Spectra in Mammography

Introduction: Average glandular dose calculation in mammography with Mo-Rh target-filter and dose calculation for different situations is accurate and fast. Material and Methods: In this research, first of all, x-ray spectra of a Mo target bombarded by a 28 keV electron beam with and without a Rh filter were calculated using the MCNP code. Then, we used the Sobol-Wu parameters to write a FORTRA...

متن کامل

Impact of Photon Spectra on the Sensitivity of Polymer Gel Dosimetry by X-Ray Computed Tomography

Introduction: The purpose of the current study was to investigate the effect of X-ray spectra on the sensitivity of a polymer gel dosimeter imaged with a conventional computed tomography (CT) scanner. Material and Methods: The whole process of CT imaging of an irradiated polymer gel was simulated by MCNPX Monte Carlo (MC) code. The imaging of polyacrylamide gel was accomplished by means of a co...

متن کامل

Unfolding X-ray spectrum in the diagnostic range using the Monte Carlo Code MCNP5

Introduction: Unfolding X-ray spectrum is a powerful tool for quality control of X-ray tubes. Generally, the acquisition of the X-ray spectrum in diagnostic radiology departments is complicated and difficult due to high photon flux. Measurement of x ray spectra using radiation detectors could not be performed accurately, because of the pulse pile up. Therefore, indirect methods...

متن کامل

Assessment of Effect Technical Directional Bremsstrahlung Splitting (DBS) on Spectra and Parameters of Simulation with Monte carlo Method BEAMnrc Code (Study Monte Carlo)

Introduction: Previous studies have shown that a Monte Carlo method for the transportations photon beam in medical linear accelerator is a good way. Strip of simulation can be used to measure the dose distribution in phantoms and patients' body. EGSnrc Code is the only code written for use in the field of radiation therapy that has many subset codes that BEAMnrc code is an impo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008