The St Jude Medical symmetry aortic connector system for proximal vein graft anastomoses in coronary artery bypass grafting.

نویسندگان

  • Friedrich S Eckstein
  • Luis F Bonilla
  • Lars Englberger
  • Franz F Immer
  • Todd A Berg
  • Jürg Schmidli
  • Thierry P Carrel
چکیده

OBJECTIVES A new device designed to create proximal vein graft anastomoses to the aorta in coronary artery bypass grafting was recently developed by the St Jude Medical Anastomotic Technology Group (Minneapolis, Minn). This new anastomosis system consists of a nickel-titanium (nitinol) connector, an aortic cutter, and a delivery device. METHODS The loading of the vein on the aortic connector and its delivery to the aorta are described. In 43 consecutive patients (mean age 68 +/- 10 years, age range 33-91 years), 65 proximal vein graft anastomoses were performed with the new system. Intraoperative flow rates were assessed for all grafts according to the transit time principle. RESULTS All connector anastomoses were performed without the use of any aortic clamp. Times to complete these mechanical anastomoses were less than 10 seconds in all cases. Hemostasis was instantaneous in all cases, with only 3 system failures. These connectors were easily removed so that the anastomoses could be performed with standard suturing technique through the same aortotomy without complications. All vein grafts were patent at the end of the procedure, and there were no intraoperative or postoperative complications related to the device. CONCLUSIONS The aortic connector system was easy to handle and allowed quick creation of reliable, reproducible, and uniform anastomoses. In addition, anastomoses could be done without any clamping of the aorta, which is especially attractive for off-pump procedures, because aortic manipulation and therefore the risks of embolism and aortic dissection would be further minimized. In on-pump cases this technique would facilitate the single-clamp technique, again minimizing aortic manipulation.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimal target international normalized ratio for patients with mechanical heart valves.

1. Katariya K, Yassin S, Tehrani HY, Lombardi P, Masroor S, Salerno TA. Initial experience with sutureless proximal anastomoses performed with a mechanical connector leading to clampless off-pump coronary artery bypass surgery. Ann Thorac Surg 2004;77:563–7. 2. Cavendish JJ, Penny WF, Madani MM, et al. Severe ostial saphenous vein graft disease leading to acute coronary syndromes following prox...

متن کامل

Technique for using the St. Jude aortic connector in anastomosis with a composite graft of saphenous vein and radial artery.

We presented a technique for using the St. Jude Aortic Connector System in anastomosis with a composite graft of saphenous vein and radial artery. This technique has not been reported in the previous literature. Our technique could improve some disadvantages of the St. Jude Aortic Connector and allow this device to be used in off-pump coronary artery bypass grafting (OPCAB).

متن کامل

Initial experience with proximal anastomoses performed with a mechanical connector.

BACKGROUND The Symmetry Bypass System Aortic Connector (St Jude Medical, Inc) is a novel device for the construction of sutureless proximal anastomoses. The connector allows attachment of saphenous vein grafts to the aorta without requiring aortic clamping. We report our initial clinical experience with this device. METHODS In a 2-month period from May to July 2001, a total of 139 consecutive...

متن کامل

First clinical results with a new mechanical connector for distal coronary artery anastomoses in CABG.

BACKGROUND Coronary anastomoses are currently primarily carried out with the use of running nonabsorbable sutures. Recently, a renewed interest has developed for facilitated mechanical anastomotic devices especially for minimal invasive techniques or limited access surgery. The initial experience with the first successful creation of mechanical vein-to-coronary artery anastomoses in humans is r...

متن کامل

eComment: Aortic connectors in coronary artery surgery.

do not decrease embolic debris compared with conventional anastomoses in CABG. Eur J Cardiothorac Surg 2004;25:993–1000. w3x Bergsland J, Hol PK, Lingas PS, Lundblad R, Rein KA, Andersen R, Mork BE, Halvorsen S, Mujanovic E, Kabil E, Svennevig JL, Fosse E. Intraoperative and intermediate-term angiographic results of coronary artery bypass surgery with Symmetry proximal anastomotic device. J Tho...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Journal of thoracic and cardiovascular surgery

دوره 123 4  شماره 

صفحات  -

تاریخ انتشار 2002