INTRODUCTION An imaging diagnosis after an iterative cesarean delivery is reviewed demonstrating a fine ultrasound-pathologic correlation. CASE PRESENTATION A 33-year-old woman (G3, P3) presented referring intense dysmenorrhea and intermenstrual spotting since her third cesarean delivery, 1 year before. A cesarean section dehiscence with utero-peritoneal fistula was diagnosed by transvaginal ultrasound. CONCLUSION We can conclude that transvaginal two-dimensional power Doppler and three-dimensional ultrasound are highly accurate in detecting cesarean section dehiscence and uterine fistula.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Role of Three Dimensional Transvaginal Ultrasound in Detection of Intrauterine Device Displacement in Post Caesarean Section: A Case Report

Intrauterine Devices (IUDs) are used as an efficient and inexpensive method of contracep¬tion. Contraceptive efficacy depends on the intrauterine location of IUD and intrauterine displacement of the IUD leads to decreased contraceptive efficacy. Expulsion of IUD and its penetration into myometrium is one of the complications of IUD. In cases where IUDs are not detected by ultrasound method, in ...

متن کامل

Three-dimensional Power Doppler Ultrasonographic Evaluation of Induced Cystitis in Dogs

Objectives: The aim of this study was to investigate if three-dimensional power Doppler (3DPD) ultrasound (US) can detect bacterial cystitis in dogs better than two-dimensional (2D) US. Animals: Six mixed breed dogs Procedures: Ten ml of 0.1% alcoholic solution of salicylic acid was entered into the urinary bladder of six male mixed-breed dogs by catheter. Twenty four hours later, culture sol...

متن کامل

Two and Three Dimensional Ultrasound Assessment of Cesarean Section Scars in Pregnant Women with Previous One or Two Cesarean Section and Its Correlation to Intraoperative Findings

The risk of uterine scar dehiscence and uterine rupture is inversely related to the lower uterine segment (LUS) thickness as measured by ultrasound. Three dimensional ultrasound can increase the reliability of ultrasound in prediction of scar dehiscence. Transvaginal three dimensional ultrasound measurement of the muscular layer thickness of the lower uterine segment seems to be the most reliab...

متن کامل

Uterocutaneous Fistula Following Cesarean Section: Successful Management of a Case

A uterocutaneous fistula is a rare clinical presentation that occurs following Cesarean section and other pelvic operations. There are only a few reports discussing the treatments. We describe a patient with successful surgical management and review the literature. A 25-year-old woman referred to our department 13 months after her first Cesarean section. She had a history of an abdominal mass a...

متن کامل

Three-Dimensional Color Doppler Ultrasonography Study of Normal Liver Vascular Pattern in Dog

Objective- To create three-dimensional model of the dog's liver vessels by using threedimensionalcolor Doppler ultrasonography which can be used for surgery planning,tumor detecting, transplantation, and other diagnostic or treatment project.Design- Descriptive studyAnimals- 6 mixed breed dog, 1.6-1.7 years old, 18-20 kg weightProcedures- The liver was found by two-dimensional scan initially th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2009