Intuitive Surgical Navigation System for Dental Implantology by Using Retinal Imaging Display
نویسندگان
چکیده
As dental implants have become an established treatment, their application to aggressive cases with insufficient quantity and quality of bone has increased. To perform safe and precise surgery, overcoming these difficulties, computer-assisted systems have been developed (Jabero et al., 2006). There are two major classes of these systems, that is, a computer-guided (static) system (Schneider et al., 2009) and a computer-navigated (dynamic) system (Jung et al., 2009). The computer-guided system such as SimPlant software and SurgiGuide (Materialize Dental Inc., USA), NobelGuide (Nobel Biocare Management AG, Sweden), and 10DR (10DR JAPAN Co., Ltd., Japan) are a surgical template based system which can simulate an optimal implant location, angle, direction, depth and size pre-operatively. Our system, BoneNavi (Bionic Inc., Japan), has also been developed to simulate implant placement and the surgical template fabrication for dental implant surgery (Ohtani et al., 2009) and applied in more than 200 clinical cases in Japan (Sohmura et al., 2009). On the other hand, the computer-navigated system such as IGI system (Image Navigation Ltd., USA) offers freehand implant navigation empowered by highly accurate motion tracking technology that tracks the positions of the dental drill and patient throughout the surgery (Casap et al., 2004). It has also already been applied in clinical cases (Casap et al., 2005 & 2008). Advantages and disadvantages of the computerguided system and the computer-navigated system are shown in Table 1. Unlike an open chest surgery and an open abdominal surgery, looking away from the oral cavity (narrow space (Fig.1)) intra-operatively involve a risk of operation errors in case of a dental implant surgery. However, with conventional systems, surgeons have to manipulate instruments in the patient’s oral cavity while watching a surgical monitor as shown in Fig.2(a) and they feel anxious during operations. To overcome this problem, we have been developed a novel surgical navigation system by combining the retinal imaging display (RID) and the augmented reality (AR) techniques
منابع مشابه
Computer-aided navigation in dental implantology: 7 years of clinical experience.
PURPOSE This long-term study gives a review over 7 years of research, development, and routine clinical application of computer-aided navigation technology in dental implantology. Benefits and disadvantages of up-to-date technologies are discussed. MATERIALS AND METHODS In the course of the current advancement, various hardware and software configurations are used. In the initial phase, unive...
متن کامل92-98 Casap
Computerized navigation surgery has evolved to facilitate minimally invasive procedures, the gold standard of surgery today. While flapless implant surgery may be clinically beneficial, it has generally been perceived as a blind procedure limited to straightforward cases that do not pose a risk of cortical plate perforation. The objective of this report is to describe a protocol for flapless im...
متن کاملReal-time 3D image-guided navigation system based on integral videography
A surgical navigation system that utilizes real-time three-dimensional (3-D) image was developed. It superimposes the real, intuitive 3-D image for medical diagnosis and operation. This system creates 3-D image based on the principle of integral photography (IP), which can display geometrically accurate 3-D autostereoscopic images and reproduce motion parallax without any need of special device...
متن کاملIntra-operative Real-Time 3-D Information Display System Based on Integral Videography
A real-time 3-D surgical navigation system that superimposes the real, intuitive 3-D image for medical diagnosis and operation was developed in this paper. This system creates 3-D image based on the principle of integral photography (IP), named “Integral Videography (IV)”, which can display geometrically accurate 3-D image and reproduce motion parallax without any need of special devices. 3-D i...
متن کاملAccuracy of Dynamic Navigation for Dental Implant Placement-Model-Based Evaluation.
The purpose of this model-based study was to determine the accuracy of placing dental implants using a new dynamic navigation system. This investigation focuses on measurements of overall accuracy for implant placement relative to the virtual plan in both dentate and edentulous models, and provides a comparison with a meta-analysis of values reported in the literature for comparable static guid...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2012