Influence of Mitral Valve Morphology on Double - Balloon Catheter Balloon Valvuloplasty in Patients With Mitral Stenosis
نویسنده
چکیده
To determine if mitral valve morphology influences the results of double-balloon catheter balloon valvuloplasty (CBV) for mitral stenosis, two-dimensional echocardiography was performed in 33 patients before CBV. The two-dimensional echocardiographic features of leaflet motion, leaflet thickness, subvalvular disease, and commissural calcium and 14 pre-CBV clinical and hemodynamic variables were then correlated to the immediately post-CBV mitral valve area (MVA). At 3 months after CBV, the two-dimensional echocardiographic features of patients with a 25% or greater decrease in MVA were analyzed to determine whether mitral valve morphology had influenced early results. Leaflet motion had a significant relation with the immediately post-CBR MVA (r=0.67, y=4.5x+0.29, and SEE=0.45). Leaflet thickness had a weak and negative relation (r= -0.48, y= -0.17x+ 2.6, and SEE= 0.53) with the immediately post-CBR MVA. Subvalvular disease and commissural calcium had no significant relation to the immediately post-CBV MVA. When leaflet motion and leaflet thickness were considered as grades of mild, moderate, and severe and assigned a score of 0-2, patients with more severe disease (total score, 3 or 4) had a significantly lower MVA immediately after CBV (1.4+±0.4 cm2) than patients with moderate disease (score, 1-2; MVA, 2.0+0.5 cm2; p<0.05) or mild disease (score, 0; MYA, 2.6+±0.6 cm2; p<0.05). In 96% of patients with a total score of 0-2, the immediately post-CBV MVA was more than 1.4 cm2, whereas only 29% of patients with a total score of 3-4 had an immediately post-CBV MVA of more than 1.4 cm2. Analysis of all two-dimensional echocardiographic features showed that leaflet motion score had the strongest influence on the post-CBV MVA (p<0.001). When all two-dimensional echocardiographic, clinical, and hemodynamic variables were included, leaflet motion, effective balloon dilating area, and cardiac output were the strongest predictors of the immediate post-CBV MYA. No two-dimensional echocardiographic feature predicted patients with an early reduction in MYA at 3 months after CBV. Quantitative assessment of leaflet motion and leaflet thickness by two-dimensional echocardiography is helpful in understanding and predicting the immediate results of double-balloon CBV of mitral stenosis; pre-CBV measurement of leaflet motion and the effective balloon dilating area used in the procedure are the strongest predictors of the MVA obtained by double-balloon CBV. (Circulation 1989;80:515-524)
منابع مشابه
SHORT TERM CLINICAL OUTCOME OF PERCUTANEOUS BALLOON MITRAL VALVULOPLASTY VERSUS SURGICAL CLOSED MITRAL COMMISSUROTOMY
BaIlon mitral valvuloplasty and closed mitral valve conunissurotomy were performed in 450 and 127 patients, respectively. Also, 254 patients with severe mitral stenosis were enrolled in a prospective randomized trial comparing the two procedures. Immediately after balloon mitral valvuloplasty, mean left atrial pressure was 11.38±3.54 mmHg, transmitral valve gradient was 1.8±2 mmHg, and mit...
متن کاملImmediate Results of Percutaneous Mitral Balloon Valvuloplasty in Patients with Mitral Stenosis
Introduction: Mitral stenosis is a prevalent valvular disease in developing countries. Percutaneous mitral balloon valvuloplasty (PMBV) is the gold standard treatment. The main objective of this study was to assess the initial results of PMBV in patients with mitral stenosis during 16 years (2002-2018) in Mashhad, Iran. Materials and Methods: From April 2002 to March 2018, 770 patients underwen...
متن کاملInfluence of mitral valve morphology on double-balloon catheter balloon valvuloplasty in patients with mitral stenosis. Analysis of factors predicting immediate and 3-month results.
To determine if mitral valve morphology influences the results of double-balloon catheter balloon valvuloplasty (CBV) for mitral stenosis, two-dimensional echocardiography was performed in 33 patients before CBV. The two-dimensional echocardiographic features of leaflet motion, leaflet thickness, subvalvular disease, and commissural calcium and 14 pre-CBV clinical and hemodynamic variables were...
متن کاملDeflation failure of Accura Balloon In Left Atrium During Balloon Mitral Valvuloplasty
Currently Percutaneous Balloon Mitral Valvuloplasty has established itself as a standard treatment for patients with severe mitral stenosis. A patient with severe mitral stenosis was posted for the above procedure. After dilatation of mitral valvular apparatus the Accura balloon failed to deflate on repeated aspirations, probably due to rupture of internal lumen. Finally, a guide wire was passe...
متن کاملDouble-transseptal, double-balloon valvuloplasty for congenital mitral stenosis.
BACKGROUND Eight patients with severe congenital mitral stenosis underwent double transseptal, double-balloon valvuloplasty; two had isolated congenital mitral stenosis, six had additional cardiac defects, and one had previous surgical valvotomy. Ages ranged from 0.6 to 36 years (median, 9 years). METHODS AND RESULTS All procedures were tolerated well. After valvuloplasty, the left atrial a w...