Coherent anti-stokes Raman scattering (CARS) microscopy: a novel technique for imaging the retina.

نویسندگان

  • Omid Masihzadeh
  • David A Ammar
  • Malik Y Kahook
  • Tim C Lei
چکیده

PURPOSE To image the cellular and noncellular structures of the retina in an intact mouse eye without the application of exogenous fluorescent labels using noninvasive, nondestructive techniques. METHODS Freshly enucleated mouse eyes were imaged using two nonlinear optical techniques: coherent anti-Stokes Raman scattering (CARS) and two-photon autofluorescence (TPAF). Cross sectional transverse sections and sequential flat (en face) sagittal sections were collected from a region of sclera approximately midway between the limbus and optic nerve. Imaging proceeded from the surface of the sclera to a depth of ∼60 μm. RESULTS The fluorescent signal from collagen fibers within the sclera was evident in the TPAF channel; the scleral collagen fibers showed no organization and appeared randomly packed. The sclera contained regions lacking TPAF and CARS fluorescence of ∼3 to 15 μm in diameter that could represent small vessels or scleral fibroblasts. Intense punctate CARS signals from the retinal pigment epithelial layer were of a size and shape of retinyl storage esters. Rod outer segments could be identified by the CARS signal from their lipid-rich plasma membranes. CONCLUSIONS CARS microscopy can be used to image the outer regions of the mammalian retina without the use of a fluorescent dye or exogenously expressed recombinant protein. With technical advancements, CARS/TPAF may represent a new avenue for noninvasively imaging the retina and might complement modalities currently used in clinical practice.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Vibrational Imaging with High Sensitivity via Epidetected Coherent Anti-Stokes Raman Scattering Microscopy

We demonstrate theoretically and experimentally a novel epidetection scheme for coherent anti-Stokes Raman scattering (CARS) microscopy that significantly improves the detection sensitivity. Calculations show that epidetected CARS (E-CARS) signals are present for scatterers smaller than the wavelength of light, whereas the large background signals from the surrounding bulk solvent are suppresse...

متن کامل

Coherent anti-Stokes Raman scattering microscopy using tightly focused radially polarized light.

We report a radially polarized coherent anti-Stokes Raman scattering (RP-CARS) microscopy for facilitating longitudinally oriented molecules detection. We observe that under tight focusing of radially polarized pump and Stokes light fields with a high-NA objective, RP-CARS radiation from molecules oriented along the longitudinal direction is approximately threefold stronger than that using line...

متن کامل

Heterodyne coherent anti-Stokes Raman scattering (CARS) imaging.

We have achieved rapid nonlinear vibrational imaging free of nonresonant background with heterodyne coherent anti-Stokes Raman scattering (CARS) interferometric microscopy. This technique completely separates the real and imaginary responses of nonlinear susceptibility chi(3) and yields a signal that is linear in the concentration of vibrational modes. We show that heterodyne CARS microscopy pe...

متن کامل

Coherent Anti-Stokes Raman Scattering Microscopy: Instrumentation, Theory, and Applications

Coherent anti-Stokes Raman scattering (CARS) microscopy permits vibrational imaging with high-sensitivity, high speed, and three-dimensional spatial resolution. We review recent advances in CARS microscopy, including experimental design, theoretical understanding of contrast mechanisms, and applications to chemical and biological systems. We also review the development of multiplex CARS microsp...

متن کامل

Abstract Submitted for the MAR06 Meeting of The American Physical Society Suppression of Non-Resonant Background in Broadband Coher- ent Anti-Stokes Raman Scattering Microscopy with Interferometry1 TAK

Submitted for the MAR06 Meeting of The American Physical Society Suppression of Non-Resonant Background in Broadband Coherent Anti-Stokes Raman Scattering Microscopy with Interferometry1 TAK KEE, MARCUS CICERONE, National Institute of Standards and Technology — We demonstrate an interferometric technique for suppressing non-resonant background in broadband coherent anti-Stokes Raman scattering ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 54 5  شماره 

صفحات  -

تاریخ انتشار 2013