Accuracy of the SpaceLabs 90207, Novacor DIASYS 200, Del Mar Avionics Pressurometer IV and Takeda TM-2420 ambulatory systems according to British and American criteria.

نویسندگان

  • E O'Brien
  • F Mee
  • N Atkins
  • K O'Malley
چکیده

Ambulatory blood pressure measurement, which has been confined to research for many years, is now an accepted investigation in clinical practice [ l ] . In an effort to ensure that the devices meet the requirements of clinical practice the British Hypertension Society (BHs) has published a comprehensive protocol for the evaluation of blood pressure measuring devices with special reference to ambulatory systems [2]. Four ambulatory systems, the SpaceIabs 90207 [3], the Novacor DIASYS 200 [4], the Del Mar Avionics Pressurometer IV [5] and the Takeda TM-2420 [6] have now been evaluated according to the BHS protocol. The evaluation was performed under standardized conditions for each ambulatory system, allowing comparison between devices.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ambulatory blood pressure measurement in the diagnosis and management of hypertension.

Before the diagnostic potential of 24-hour non-invasive BP measurement can be assessed, the accuracy of ambulatory recorders must be established, and normal reference values determined. The accuracy criteria of four ambulatory BP measuring systems (the SpaceLabs 90207, the Novecor DIASYS 200, the Takeda TM-2420 and the Del Mar Avionics Pressurometer IV) have been assessed according to the Briti...

متن کامل

Comparative accuracy of six ambulatory devices according to blood pressure levels.

OBJECTIVE To assess the accuracy of six ambulatory blood pressure measuring systems at low, medium and high blood pressures. RESULTS The CH-Druck, Profilomat, SpaceLabs 90207 and Novacor DIASYS 200R, having previously achieved A to C grading for systolic and diastolic blood pressures according to the British Hypertension Society (BHS) protocol and having fulfilled the criteria of the Associat...

متن کامل

Twenty-four-hour ambulatory blood pressure monitoring: a review of validation data.

As the clinical applications for 24-h ambulatory blood pressure monitoring expand, market demands increase, and there are now at least 13 manufacturers producing elaborate and expensive systems for recording 24-h ambulatory pressures. It is often difficult to assess the accuracy and performance characteristics of these devices and failure to standardize validation makes it difficult to compare ...

متن کامل

State of the market. A review of ambulatory blood pressure monitoring devices.

The introduction of 24-hour ambulatory blood pressure measurement into clinical practice created a large market for ambulatory blood pressure measurement devices. Forty-three such devices from 31 manufacturers or suppliers are now available to satisfy a market demand that is likely to increase. The aim of this article is to identify the devices available and then to examine critically any valid...

متن کامل

Accuracy of the SpaceLabs 90207 ambulatory blood pressure measuring system in normotensive pregnant women determined by the British Hypertension Society protocol.

The SpaceLabs 90207 monitor (Redmond, Washington, USA) for ambulatory blood pr-nue measurement u-as evaluated according to the protocol of the British Hypertension Society (BHS) 111 in normotmsive pregnant women. We have previously evaluated the SpaceLabs 90207 in nonnotmsive and hypertensive men and non-pregnant women according to the BHS protocol (21, In this evaluation the device achieved B ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of hypertension. Supplement : official journal of the International Society of Hypertension

دوره 9 6  شماره 

صفحات  -

تاریخ انتشار 1991