The Correction of Focal Point Displacement Caused by the Refraction of the Beams in High-Intensity Focused Ultrasound

نویسندگان

  • Mohammad Rezaei
  • Karim Khoshgard
  • Mehdi Mousavi
چکیده

Nowadays, high-intensity focused ultrasound (HIFU) as nonionizing radiation is used for cancer treatment. Basically, the function of HIFU is similar to conventional ultrasound. Ultrasound beams are perverted when crossing the border of different environments. This decreases the beam's focus within the tumor and may induce damage to the normal tissues. In this study, we aim to develop appropriate algorithms for correcting the focal point displacement duced by the beam's refraction. First, the level of displacement due to difference in two specific tissues was calculated for one element of the transducer and, then, it extended to all of the elements. Finally, a new focal point was calculated, which is considered as a desired focal point of the transducer in which the maximum temperature occurs. Designed algorithms were implemented in MATLAB software. A HIFU simulator (by the Food and Drug Administration of US) was used to simulate HIFU therapy. The proposed algorithm was tested on four models with two layers of tissue. Results illustrated the use of proposed algorithm results for 78% correction in the focal point displacement. In addition, it was noted that a part of this displacement was caused by the absorption of the beam in the tissues. The proposed algorithm can significantly correct the focal point displacement in HIFU therapy and consequently prevent damage to the normal tissues.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی انکسار پرتوهای فراصوت در هایفوتراپی و بهینه سازی عمق کانونی مبدل فراصوت جهت افزایش دقت درمان

Background and purpose: Nowadays High-intensity focused ultrasound (HIFU) as non-ionizing radiation is used for cancer treatment. Ultrasound beams when crossing the border of two environments are refracted causing decrease in the beam focusing within a tumor. Also, it may induce damage to normal tissues. In this study, we evaluated the focal depth shift induced by ultrasonic beam refraction. ...

متن کامل

Evaluation of Ultrasonic Beam Refraction in HIFU Therapy and Focal Depth Optimization in Ultrasonic Transducer to Increase the Treatment Accuracy

Background and purpose: Nowadays High-intensity focused ultrasound (HIFU) as nonionizing radiation is used for cancer treatment. Ultrasound beams when crossing the border of two environments are refracted causing decrease in the beam focusing within a tumor. Also, it may induce damage to normal tissues. In this study, we evaluated the focal depth shift induced by ultrasonic beam refraction. Mat...

متن کامل

Numerical Study for Optimizing Parameters of High-Intensity Focused Ultrasound-Induced Thermal Field during Liver Tumor Ablation: HIFU Simulator

Introduction High intensity focused ultrasound (HIFU) is considered a noninvasive and effective technique for tumor ablation. Frequency and acoustic power are the most effective parameters for temperature distribution and the extent of tissue damage. The aim of this study was to optimize the operating transducer parameters such as frequency and input power in order to acquire suitable temperatu...

متن کامل

Investigation tow of negative refraction characters in the three different 2D phononic crystals

In this paper, a two-dimensional phononic crystal comprising of steel rod in water is investigated. Three cross- sections for this rod are considered using finite element method (EFM). We plot the equifrequency surface of the first band, because of equifrequency surface convex around the edge of the first Brillouin Zone, we guess the negative effective phononic mass and so negative refraction. ...

متن کامل

Effective Point of Measurement in Cylindrical Ion Chamber for Megavoltage Photon Beams

Introduction For dose measurement in Megavoltage (MV) photon beams with ion chambers, the effect of volume occupied by the air cavity is not negligible. Therefore, the result of measurement should be corrected with a displacement perturbation correction factor (Pdis) or using an effective point of measurement (EPOM). The aim of this study is to calculate the EPOM for cylindrical ion chamber and...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2017