Model for end-stage liver disease score predicts left ventricular assist device operative transfusion requirements, morbidity, and mortality.
نویسندگان
چکیده
BACKGROUND The Model for End-Stage Liver Disease (MELD) predicts events in cirrhotic subjects undergoing major surgery and may offer similar prognostication in left ventricular assist device candidates with comparable degrees of multisystem dysfunction. METHODS AND RESULTS Preoperative MELD scores were calculated for subjects enrolled in the University of Michigan Health System (UMHS) mechanical circulatory support database. Univariate and multiple regression analyses were performed to investigate the ability of patient characteristics, laboratory data (including MELD scores), and hemodynamic measurements to predict total perioperative blood product exposure and operative mortality. The ability of preoperative MELD scores to predict operative mortality was evaluated in subjects enrolled in the Interagency Registry of Mechanically Assisted Circulatory Support (INTERMACS), and results were compared with those from the UMHS cohort. The mean+/-SD MELD scores for the UMHS (n=211) and INTERMACS (n=324) cohorts were 13.7+/-6.1 and 15.2+/-5.8, respectively, with 29 (14%) and 19 (6%) perioperative deaths. In the UMHS cohort, median total perioperative blood product exposure was 74 units (25th and 75th percentiles, 44 and 120 units). Each 5-unit MELD score increase was associated with 15.1+/-3.8 units (beta+/-SE) of total perioperative blood product exposure. Each 10-unit increase in total perioperative blood product exposure increased the odds of operative death (odds ratio, 1.05; 95% confidence interval, 1.01 to 1.10). Odds ratios, measuring the ability of MELD scores to predict perioperative mortality, were 1.5 (95% confidence interval, 1.1 to 2.0) and 1.5 (95% confidence interval, 1.1 to 2.1) per 5 MELD units for the UMHS and INTERMACS cohorts, respectively. When MELD scores were dichotomized as >or=17 and <17, risk-adjusted Cox proportional-hazard ratios for 6-month mortality were 2.5 (95% confidence interval, 1.2 to 5.3) and 2.5 (95% confidence interval, 1.1 to 5.4) for the UMHS and INTERMACS cohorts, respectively. CONCLUSIONS The MELD score identified left ventricular assist device candidates at high risk for perioperative bleeding and mortality.
منابع مشابه
Model of end stage liver disease (MELD) score greater than 23 predicts length of stay in the ICU but not mortality in liver transplant recipients
INTRODUCTION The impact of model of end stage liver disease (MELD) score on postoperative morbidity and mortality is still elusive, especially for high MELD. There are reports of poorer patient outcome in transplant candidates with high MELD score, others though report no influence of MELD score on outcome and survival. METHODS We retrospectively analyzed data of 144 consecutive liver transpl...
متن کاملBleeding with the artificial heart: Gastrointestinal hemorrhage in CF-LVAD patients
Continuous-flow left ventricular assist devices (CF-LVADs) have significantly improved outcomes for patients with end-stage heart failure when used as a bridge to cardiac transplantation or, more recently, as destination therapy. However, its implantations carries a risk of complications including infection, device malfunction, arrhythmias, right ventricular failure, thromboembolic disease, pos...
متن کاملSystematic Left Ventricular Assist Device Implant Eligibility with Non-Invasive Assessment: The SIENA Protocol
In patients with end-stage left ventricular (LV) heart failure who receive LV assist device (LVAD) implantation, right ventricular (RV) failure represents a possible critical complication that heavily affects morbidity and mortality. Several clinical, laboratory, hemodynamic, and echocardiographic variables have been found to be associated with RV failure occurrence after surgery. Different mod...
متن کاملSeverity Assessment of Chronic Liver Disease in Children
Introduction: Chronic liver disease and cirrhosis are the most important causes of growth failure, morbidity and mortality in children. Cirrhosis consists of a variety of congenital, genetic, metabolic, and infectious causes in children. Models for predicting of chronic liver disease severity, survival, and transplantation are useful for decision-making as well as medical interventions. The mo...
متن کاملThe right ventricular failure risk score a pre-operative tool for assessing the risk of right ventricular failure in left ventricular assist device candidates.
OBJECTIVES This study sought to develop a model that estimates the post-operative risk of right ventricular (RV) failure in left ventricular assist device (LVAD) candidates. BACKGROUND Right ventricular failure after LVAD surgery is associated with increased morbidity and mortality, but identifying LVAD candidates at risk for RV failure remains difficult. METHODS A prospectively collected L...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Circulation
دوره 121 2 شماره
صفحات -
تاریخ انتشار 2010