Tumor Therapy with Heavy Ions at GSI Darmstadt
نویسنده
چکیده
In comparison to conventional photon therapy heavy-ion beams offer favourable conditions for the treatment of deep-seated local tumors. The physical depth-dose distribution in tissue is characterized by a small entrance dose and a distinct maximum (Bragg peak) near the end of range with a sharp fall-off at the distal edge. The well-defined range and the small lateral beam spread make it possible to deliver the dose with millimetre precision. In addition, heavy ions have an enhanced biological effectiveness in the Bragg peak region, which is caused by the dense ionization and the resulting reduced cellular repair rate. Furthermore, heavy ions offer the unique possibility to apply Positron Emission Tomography (PET) techniques for an in-vivo range monitoring of positron-emitting isotopes like C which are formed in nuclear fragmentation reactions. The pilot therapy unit at GSI started operation in December 1997 using C ions with energies of 80-430 MeV/u from the heavy-ion synchrotron SIS-18 and a novel fully active rasterscan system for beam delivery. So far more than 260 patients were treated with very promising clinical results. The indications comprise mainly inoperable and radio-resistant tumors of the skull base (chordoma, chondrosarcoma and others) which are located near sensitive organs such as the brain stem or the optical nerve. The treatments with a median tumor dose of 60 Gye delivered in 20 fractions were well tolerated and no significant side effects occurred. Local tumor control rates after three years follow-up time were 100% for chondrosarcomas and 81% for chordomas. The construction of a new dedicated proton/ion treatment centre (HIT) at the Radiological Clinic in Heidelberg with a planned capacity of more than 1000 patients per year has started in spring 2004. It will be equipped with one 360° isocentric Gantry system and two additional treatment rooms with horizontal beam lines. Clinical operation is expected to begin in 2007.
منابع مشابه
Investigations on BeO as a dosimeter material for hadron therapy
Hadron cancer-therapy with high-energetic heavy-ions (HI) as available at the SIS facility at GSI Darmstadt [1] as well as the research with beams stopped in biological material as realized at the UNILAC at GSI in general require the precise knowledge of the applied dose within less than 1% in most cases. Solid state detectors based on various materials read out via thermally stimulated light e...
متن کاملHeavy-ion tumor therapy: Physical and radiobiological benefits
High-energy beams of charged nuclear particles !protons and heavier ions" offer significant advantages for the treatment of deep-seated local tumors in comparison to conventional megavolt photon therapy. Their physical depth-dose distribution in tissue is characterized by a small entrance dose and a distinct maximum !Bragg peak" near the end of range with a sharp fall-off at the distal edge. Ta...
متن کاملIn-beam PET monitoring of phantom irradiation with Li-ions
In-beam PET is presently the only possibility of a beamline independent dose delivery monitoring in heavyion therapy. It is clinically implemented at the experimental heavy ion treatment facility at GSI Darmstadt. Since 1997 almost 400 patients have been treated there with C-ions while monitoring of dose application with inbeam PET has been performed. In the future it is expected to extend tumo...
متن کاملA performance study of the conceptual implementation of the GEM-tracking detector in Monte Carlo simulation
PANDA experiment (antiProton ANnihilation at DArmstadt) is one of the key projects of the future FAIR facilities to investigate the reactions of antiprotons with protons and nuclear targets. experiment is designed to serve as a completely extraordinary physical potential due to exploiting the availability of cold and high-intensity beams of antiprotons. One of the significant parts of the ...
متن کامل4D in-beam PET of moving targets for different irradiation scenarios
Introduction Ion therapy allows a high precision, tumor conformal dose application but it is very sensitive to density changes along the beam path. Intra-fractional tumor motion due to respiration increases the risk of an incorrect irradiation and thus requires a reliable dosimetry as it was done by means of 3D in-beam PET for more than 400 patients at the experimental heavy ion treatment facil...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -