Total endograft replacement of aortic arch.

نویسندگان

  • Simon Neequaye
  • Cherrie Z Abraham
چکیده

Total endovascular replacement of the aortic arch is a complex procedure that is often favoured when the pathology anatomy precludes a standard median sternotomy. Here we present the case of endograft repair in a 79 year old male with 6.5 cm arch aneurysm and 5.4 cm descending thoracoabdominal aneurysm. Following bilateral carotid-subclavian bypasses, a long 7 Fr sheath was advanced into the descending aorta through the common iliac artery purse string. A double curved long Lunderquist wire was guided to deep within the left ventricle, and the endograft carefully advanced over the wire. The graft was radiologically orientated, and deployed under asystolic conditions. Retrograde cannulation of the branches were accomplished, with carotid sheath placed into the branches followed by bridging stents. The graft delivery system was then removed. This approach obviates the need for a sternotomy, cumbersome extra-anatomic debranching, and hypothermic circulatory arrest.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Aneurysm formation at both ends of an endograft associated with maladaptive aortic changes after endovascular aortic repair in a healthy patient.

We report a case in which saccular aneurysms formed at both ends of an endograft that exhibited maladaptive aortic changes after endovascular aortic repair in a patient without significant evidence of connective tissue disease. A 66-year old male underwent thoracic endovascular aortic repair (TEVAR) for a distal aortic arch aneurysm. A follow-up computed tomography (CT) scan performed at 6 mont...

متن کامل

Infectious pseudoaneurysm at the proximal edge of the endograft, after hybrid aortic arch repair.

A 77-year old woman who underwent hybrid aortic arch repair using a Gore-TAG (Gore-Associates, Flagstaff, AZ, USA) endograft (Fig. 1A) complained of chest pain 5 months after operation. Blood cultures revealed Serratia marcescens. Computed tomography (CT) demonstrated dislocation of the endograft with formation of a pseudoaneurysm (Fig. 1B). Ascending aorta replacement with re-debranching was e...

متن کامل

Externalized Guidewires to Facilitate Fenestrated Endograft Deployment in the Aortic Arch

PURPOSE To describe a precannulated fenestrated endograft system utilizing externalized guidewires to facilitate aortic arch endovascular repair and to report its use in 2 patients with challenging anatomy. TECHNIQUE For distal arch repair, a fenestration for the left subclavian artery (LSA) is made onsite in a standard thoracic endograft tailored to the patient anatomy; it is precannulated w...

متن کامل

Direct videoscopic approach to the descending thoracic aorta for aortic arch endograft delivery: evaluation in a porcine model.

PURPOSE To examine the feasibility of a direct videoscopic approach to the descending thoracic aorta for endograft delivery to the aortic arch. METHODS A double purse-string suture was placed on the aorta of 3 pigs via a thoracoscopic approach. Subsequently, the aorta was cannulated in the center of the purse-string. A 22-F delivery catheter was advanced under fluoroscopic control over a guid...

متن کامل

Hybrid arch debranching and endograft repair in a patient with a ruptured thoracic aortic aneurysm.

Recent advances in hybrid techniques of aortic arch debranching allow for the repair of thoracic aortic arch aneurysm without requiring cardiopulmonary bypass or hypothermic circulatory arrest. We describe the repair of a ruptured proximal descending thoracic aortic aneurysm, using off-pump aortic arch debranching and antegrade transaortic deployment of a thoracic endograft in an elderly patient.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Annals of cardiothoracic surgery

دوره 2 3  شماره 

صفحات  -

تاریخ انتشار 2013