C-arm Tracking by Intensity-Based Registration of a Fiducial in Prostate Brachytherapy

نویسندگان

  • Pascal Fallavollita
  • Everette Clif Burdette
  • Danny Y. Song
  • Purang Abolmaesumi
  • Gabor Fichtinger
چکیده

Motivation: In prostate brachytherapy, intra-operative dosimetry optimization can be achieved through reconstruction of the implanted seeds from multiple C-arm fluoroscopy images. This process requires tracking of the C-arm poses. Methodology: We compute the pose of the C-arm relative to a stationary radiographic fiducial of known geometry. The fiducial was precisely fabricated. We register the 2D fluoroscopy image of the fiducial to a projected digitally reconstructed radiograph of the fiducial. The novelty of this approach is using image intensity alone without prior segmentation of the fluoroscopy image. Experiments and Results: Ground truth pose was established for each Carm image using a published and clinically tested segmentation-based method. Using 111 clinical C-arm images and ±10° and ±10 mm random perturbation around the ground-truth pose, the average rotation and translation errors were 0.62° (std=0.31°) and 0.73 mm (std= 0.55mm), respectively. Conclusion: Fully automated segmentation-free C-arm pose estimation was found to be clinically adequate on human patient data.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

C-arm Pose Estimation in Prostate Brachytherapy by Registration to Ultrasound

In prostate brachytherapy, transrectal ultrasound (TRUS) is used to visualize the anatomy, while implanted seeds can be seen in C-arm fluoroscopy. Intra-operative dosimetry optimization requires reconstruction of the implanted seeds from multiple C-arm fluoroscopy images, which in turn requires estimation of the C-arm poses. We estimate the pose of the C-arm by two-stage registration between th...

متن کامل

A dynamic dosimetry system for prostate brachytherapy

The lack of dynamic dosimetry tools for permanent prostate brachytherapy causes otherwise avoidable problems in prostate cancer patient care. The goal of this work is to satisfy this need in a readily adoptable manner. Using the ubiquitous ultrasound scanner and mobile non-isocentric C-arm, we show that dynamic dosimetry is now possible with only the addition of an arbitrarily configured marker...

متن کامل

Automatic segmentation of radiographic fiducial and seeds from X-ray images in prostate brachytherapy.

Prostate brachytherapy guided by transrectal ultrasound is a common treatment option for early stage prostate cancer. Prostate cancer accounts for 28% of cancer cases and 11% of cancer deaths in men with 217,730 estimated new cases and 32,050 estimated deaths in 2010 in the United States alone. The major current limitation is the inability to reliably localize implanted radiation seeds spatiall...

متن کامل

Registration between ultrasound and fluoroscopy or CT in prostate brachytherapy.

PURPOSE In prostate brachytherapy, transrectal ultrasound (TRUS) is used to visualize the anatomy, while implanted seeds can be visualized by fluoroscopy. Intraoperative dosimetry optimization is possible using a combination of TRUS and fluoroscopy, but requires localization of the fluoroscopy-derived seed cloud, relative to the anatomy as seen on TRUS. The authors propose to develop a method o...

متن کامل

An image-guidance system for dynamic dose calculation in prostate brachytherapy using ultrasound and fluoroscopy.

PURPOSE Brachytherapy is a standard option of care for prostate cancer patients but may be improved by dynamic dose calculation based on localized seed positions. The American Brachytherapy Society states that the major current limitation of intraoperative treatment planning is the inability to localize the seeds in relation to the prostate. An image-guidance system was therefore developed to l...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010