Spherical Deconvolution of Multichannel Diffusion MRI Data with Non-Gaussian Noise Models and Spatial Regularization

نویسندگان

  • Erick J. Canales-Rodríguez
  • Alessandro Daducci
  • Stamatios N. Sotiropoulos
  • Emmanuel Caruyer
  • Santiago Aja-Fernández
  • Joaquim Radua
  • Jesús M. Yurramendi Mendizabal
  • Yasser Iturria-Medina
  • Lester Melie-García
  • Yasser Alemán-Gómez
  • Jean-Philippe Thiran
  • Salvador Sarró
  • Edith Pomarol-Clotet
  • Raymond Salvador
  • Alexander Leemans
چکیده

Spherical deconvolution (SD) methods are widely used to estimate the intra-voxel white-matter fiber orientations from diffusion MRI data. However, while some of these methods assume a zero-mean Gaussian distribution for the underlying noise, its real distribution is known to be non-Gaussian and to depend on many factors such as the number of coils and the methodology used to combine multichannel MRI signals. Indeed, the two prevailing methods for multichannel signal combination lead to noise patterns better described by Rician and noncentral Chi distributions. Here we develop a Robust and Unbiased Model-BAsed Spherical Deconvolution (RUMBA-SD) technique, intended to deal with realistic MRI noise, based on a Richardson-Lucy (RL) algorithm adapted to Rician and noncentral Chi likelihood models. To quantify the benefits of using proper noise models, RUMBA-SD was compared with dRL-SD, a well-established method based on the RL algorithm for Gaussian noise. Another aim of the study was to quantify the impact of including a total variation (TV) spatial regularization term in the estimation framework. To do this, we developed TV spatially-regularized versions of both RUMBA-SD and dRL-SD algorithms. The evaluation was performed by comparing various quality metrics on 132 three-dimensional synthetic phantoms involving different inter-fiber angles and volume fractions, which were contaminated with noise mimicking patterns generated by data processing in multichannel scanners. The results demonstrate that the inclusion of proper likelihood models leads to an increased ability to resolve fiber crossings with smaller inter-fiber angles and to better detect non-dominant fibers. The inclusion of TV regularization dramatically improved the resolution power of both techniques. The above findings were also verified in human brain data.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Spherical deconvolution of multichannel diffusion MRI data with non- Gaussian noise models and total variation spatial regularization

1 Spherical deconvolution of multichannel diffusion MRI data with nonGaussian noise models and total variation spatial regularization Erick J. Canales-Rodríguez, Alessandro Daducci, Stamatios N. Sotiropoulos, Emmanuel Caruyer, Santiago Aja-Fernández, Joaquim Radua, Yosu Yurramendi Mendizabal, Yasser Iturria-Medina, Lester Melie-García, Yasser Alemán-Gómez, Jean-Philippe Thiran, Salvador Sarró, ...

متن کامل

Determination of Fiber Direction in High Angular Resolution Diffusion Images using Spherical Harmonics Functions and Wiener Filter

Diffusion tensor imaging (DTI) MRI is a noninvasive imaging method of the cerebral tissues whose fibers directions are not evaluated correctly in the regions of the crossing fibers. For the same reason the high angular resolution diffusion images (HARDI) are used for estimation of the fiber direction in each voxel. One of the main methods to specify the direction of fibers is usage of the spher...

متن کامل

Mesh-based spherical deconvolution: A flexible approach to reconstruction of non-negative fiber orientation distributions

Diffusion-weighted MRI has enabled the imaging of white matter architecture in vivo. Fiber orientations have classically been assumed to lie along the major eigenvector of the diffusion tensor, but this approach has well-characterized shortcomings in voxels containing multiple fiber populations. Recently proposed methods for recovery of fiber orientation via spherical deconvolution utilize a sp...

متن کامل

3D Bayesian Regularization of Diffusion Tensor MRI Using Multivariate Gaussian Markov Random Fields

3D Bayesian regularization applied to diffusion tensor MRI is presented here. The approach uses Markov Random Field ideas and is based upon the definition of a 3D neighborhood system in which the spatial interactions of the tensors are modeled. As for the prior, we model the behavior of the tensor fields by means of a 6D multivariate Gaussian local characteristic. As for the likelihood, we mode...

متن کامل

Fast and Accurate Multi-tissue Deconvolution Using SHORE and H-psd Tensors

We propose a new regularization for spherical deconvolution in diffusion MRI. It is based on observing that higher-order tensor representations of fiber ODFs should be H-psd, i.e., they should have a positive semidefinite (psd) matrix HT . We show that this constraint is stricter than the currently more widely used non-negativity, and that it can be enforced easily using quadratic cone programm...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2015