Evaluating retinal function in age-related maculopathy with the ERG photostress test.

نویسندگان

  • Alison M Binns
  • Tom H Margrain
چکیده

PURPOSE To evaluate the diagnostic potential of the electroretinogram (ERG) photostress test and the focal cone ERG in age-related maculopathy (ARM). METHODS The cohort comprised 31 patients with ARM and 27 age-matched control subjects. The ERG photostress test was used to monitor cone adaptation after intense light adaptation. Focal 41- and 5-Hz cone ERGs were recorded monocularly (central 20 degrees) to assess steady state retinal function. Univariate analysis identified electrophysiological parameters that differed between groups, and receiver operating characteristic (ROC) curves were constructed to assess their diagnostic potential. Logistic regression analysis determined the diagnostic potential of a model incorporating several independent predictors of ARM. RESULTS The rate of recovery of the ERG photostress test was reduced (recovery was slower) in subjects with ARM. The parameter exhibited good diagnostic potential (P = 0.002, area under ROC curve = 0.74). The implicit times of the 5-Hz (a-wave, P = 0.002; b-wave, P < 0.001) and the 41-Hz (P < 0.001) focal cone ERGs were increased, and the 41-Hz focal cone ERG amplitude (P = 0.003) and focal to full-field amplitude ratio (P = 0.001) were reduced in the ARM group. Logistic regression analysis identified three independent predictors of ARM, including the rate of recovery of the ERG photostress test. CONCLUSIONS Early ARM has a marked effect on the kinetics of cone adaptation. The clinical application of the ERG photostress test increases the sensitivity and specificity of a model for the diagnosis of ARM. Improved assessment of the functional integrity of the central retina will facilitate early diagnosis and evaluation of therapeutic interventions.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Photostress Testing Device for Diagnosing Retinal Disease

Retinal diseases such as Age-Related Macular Degeneration (ARMD) affect nearly one in three elderly patients. ARMD damages the central vision photoreceptors in the fovea. The Photostress Test is a simple technique for testing for the early effects of ARMD. Here, the illumination sources in a novel self-administered Photostress Testing device were modeled for safety and distribution in illuminat...

متن کامل

Electrophysiological findings in patients with dengue-related maculopathy.

OBJECTIVE To assess visual function in patients with dengue maculopathy using electrophysiological tests. METHODS Fifteen consecutive patients with dengue fever who experienced vision loss between July 2004 and July 2005 were included in this review. Full-field electroretinograms (ERG), pattern ERGs, and multifocal ERGs were performed. RESULTS The most common electrophysiological finding (6...

متن کامل

Impact of aging and age-related maculopathy on inactivation of the a-wave of the rod-mediated electroretinogram

PURPOSE To examine the impact of aging and age-related maculopathy (ARM) on the activation of phototransduction in rod photoreceptors by measuring the a-wave of the flash, full-field electroretinogram (ERG). METHODS Enrollees consisted of older adults (> or = 60 years of age) in normal retinal health (n = 41) and those with early (n = 39) or late ARM (n = 7), in whom disease presence and seve...

متن کامل

Clinical studies on progressive retinal atrophy in 31 dogs

During a 2-year period, 31 cases of a hereditary retinal degeneration in dogs bred in India were found mainly suspected for progressive retinal atrophy (PRA) with typical history of initial nyctalopia followed by hemeralopia. Out of 31 PRA suspected dogs, 8 dogs (26%) were from the age group of 1-5 years, 15 (48%) 6-10 years and the rest (26%) 11-15 years. The most predominant breed was Spitz (...

متن کامل

Reliability, normative data, and the effect of age-related macular disease on the Eger Macular Stressometer photostress recovery time.

PURPOSE To assess repeatability and reproducibility, to determine normative data, and to investigate the effect of age-related macular disease, compared with normals, on photostress recovery time measured using the Eger Macular Stressometer (EMS). METHOD The study population comprised 49 healthy eyes of 49 participants. Four EMS measurements were taken in two sessions separated by 1 h by two ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 48 6  شماره 

صفحات  -

تاریخ انتشار 2007