Doppler blood pressure measurement in pigs during anaesthesia.

نویسندگان

  • Gabrielle C Musk
  • Renata S Costa
  • Jonathan Tuke
چکیده

To determine the accuracy of Doppler blood pressure measurement in anaesthetised pigs eight large white pigs (Sus scrofa) were anaesthetised with zolazepam and tiletamine as Zoletil 100 (4 mg/kg) and xylazine (2 mg/kg) by intramuscular injection followed by isoflurane in 100% oxygen. Blood pressure measurements were recorded using a Doppler probe on the radial artery and a catheter in the femoral artery connected to a transducer. The sample mean of the Doppler measurements were compared with the sample mean of the invasive systolic arterial blood pressure while accounting for the heart rate, end-tidal CO2 and temperature. The predicted error of the Doppler was greatest when pigs were hypotensive and normothermic: 11 mmHg (CI: 6-15). Doppler measurements should be interpreted with caution in anaesthetised pigs that are hypotensive and normothermic.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Presentation of a Non-invasive Method of Estimating Arterial Stiffness by Modeling Blood Flow and Arterial Wall Based on the Determination of Elastic Module of Arterial Wall

Introduction: Arterial stiffness is an important predictor of cardiovascular risk. Several indices have been  introduced to estimate the arterial stiffness based on the changes in the brachial blood pressure. Since the  substitution  of  the  blood  pressure  changes  in  the  central  arteries  such  as  carotid  with  the  blood  pressure  changes in the brachial results in error in the blood...

متن کامل

Measurements of systolic time intervals using a transoesophageal pulsed echo-Doppler.

Measurement of systolic time intervals (STI), an index of left ventricular (LV) systolic function, is usually labour intensive and requires considerable expertise to perform accurately. We have evaluated the accuracy of an automated, continuous and non-invasive STI measurement technique using a descending aortic blood velocity Doppler signal obtained using a transoesophageal echo-Doppler system...

متن کامل

Effects of sodium nitroprusside on splanchnic microcirculation in a resuscitated porcine model of septic shock.

BACKGROUND We tested the hypothesis that sodium nitroprusside (SNP) might improve the impairment of hepatosplanchnic microcirculatory blood flow (MBF) in septic shock. METHODS Fourteen pigs were anaesthetized and their lungs mechanically ventilated. Sepsis was induced with i.v. infusion of live Pseudomonas aeruginosa [1x10(8) colony forming units (CFU) ml(-1) kg(-1)] for 1 h. Sixty minutes la...

متن کامل

High-intensity transient signals during laparoscopic surgery in children.

BACKGROUND Laparoscopic interventions in children gain increasing popularity. Pneumoperitoneum as applied during laparoscopic surgery can induce gas emboli formation, but it is unclear whether this is associated with cerebral embolic events. To investigate the hypothesis that pneumoperitoneum causes cerebral emboli in children, the number and intensity of high-intensity transient signals (HITS)...

متن کامل

Cerebral effects of nitrous oxide during isoflurane-induced hypotension in the pig.

We have studied the effects of nitrous oxide on cerebral blood flow (CBF), cerebral blood flow velocity (CBFV) and intracranial pressure (ICP) during isoflurane-induced hypotension in 10 pigs. CBF was measured using laser Doppler flowmetry, CBFV in the right middle cerebral artery was calculated using Doppler ultrasound and ICP was measured using an extradural ICP monitor. Each animal was studi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Research in veterinary science

دوره 97 1  شماره 

صفحات  -

تاریخ انتشار 2014