Using Accurate Solid Angle Tools when Comparing EDS Detector Geometries

نویسندگان

  • Patrick Camus
  • Reinhard Buchhold
چکیده

Analysts should strive for the EDS system that provides the highest efficiency for their analytical work. For detectors, that typically means starting with the geometry with the best solid angle (SA) value. Manufacturers should be designing interfaces to maximize the solid angle of the detectors without compromising the integrity of the electron columns. Accurate modeling of the solid angle is required for both analysts and manufacturers so that everyone is satisfied with the detector performance. This paper will show that new solid angle calculations must be used for accurate solid angle modeling. Application of these models to new geometries illustrates the performance benefits of creative geometric designs.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Calculation of Source-detector Solid Angle, Using Monte Carlo Method, for Radioactive Sources with Various Geometries and Cylindrical Detector

In this paper source-detector solid angle calculation has been studied by Monte Carlo method, and a computer program is represented. Since most experimental works in nuclear physics are done by using of cylindrical detectors, the solid angle of this type of detector is calculated for various sources. The source in various shapes of a point, cylinder, sphere, or rectangle, may be located in any ...

متن کامل

Investigation of Multiple, Large Area EDS Detectors on an SEM Capable of Various Mounting Geometries for Optimal EDS Analysis

It is common knowledge that collecting EDS data with dual large area SDD detectors from 180 degree opposing geometries has proven extremely beneficial with highly topographic samples [REF 1]. Traditionally, using high kV, the high count rates achievable from today’s SDD EDS detectors have been used to significantly reduce the time needed to acquire the statistical data necessary for X-ray analy...

متن کامل

Probe current determination in analytical TEM/STEM and its application to the characterization of large area EDS detectors.

A simple procedure, which enables accurate measurement of transmission electron microscopy (TEM)/STEM probe currents using an energy loss spectrometer drift tube is described. The currents obtained are compared with those measured on the fluorescent screen to enable the losses due to secondary and backscattered electrons to be determined. The current values obtained from the drift tube allow th...

متن کامل

Analytical formulae for calculation of X-ray detector solid angles in the scanning and scanning/transmission analytical electron microscope.

Closed form analytical equations used to calculate the collection solid angle of six common geometries of solid-state X-ray detectors in scanning and scanning/transmission analytical electron microscopy are presented. Using these formulae one can make realistic comparisons of the merits of the different detector geometries in modern electron column instruments. This work updates earlier formula...

متن کامل

Calibration of the High Purity Germanium Gamma-Ray Spectrometer in CERT,ABU Zaria, Nigeria

Gamma-ray spectrometry is a very powerful tool for radioactivity measurements. The gamma-ray spectrometer laboratory in Centre for Energy Research and Training (CERT), Ahmadu Bello University, Zaria, Nigeria is accredited to perform measurements of radioactive content of samples collected from the environment, food chain or industrial products with the aid of a high resolution HPGe detector. Fo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014