Randomized trial of a distal embolic protection device during percutaneous intervention of saphenous vein aorto-coronary bypass grafts.
نویسندگان
چکیده
BACKGROUND Stents provide effective treatment for stenotic saphenous venous aorto-coronary bypass grafts, but their placement carries a 20% incidence of procedure-related complications, which potentially are related to the distal embolization of atherosclerotic debris. We report the first multicenter randomized trial to evaluate use of a distal embolic protection device during stenting of such lesions. METHODS AND RESULTS Of 801 eligible patients, 406 were randomly assigned to stent placement over the shaft of the distal protection device, and 395 were assigned to stent placement over a conventional 0.014-inch angioplasty guidewire (control group). The primary end point-a composite of death, myocardial infarction, emergency bypass, or target lesion revascularization by 30 days-was observed in 65 patients (16.5%) assigned to the control group and 39 patients (9.6%) assigned to the embolic protection device (P=0.004). This 42% relative reduction in major adverse cardiac events was driven by myocardial infarction (8.6% versus 14.7%, P=0.008) and "no-reflow" phenomenon (3% versus 9%, P=0.02). Clinical benefit was seen even when platelet glycoprotein IIb/IIIa receptor blockers were administered (61% of patients), with composite end points occurring in 10.7% of protection device patients versus 19.4% of control patients (P=0.008). CONCLUSIONS Use of this distal protection device during stenting of stenotic venous grafts was associated with a highly significant reduction in major adverse events compared with stenting over a conventional angioplasty guidewire. This demonstrates the importance of distal embolization in causing major adverse cardiac events and the value of embolic protection devices in preventing such complications.
منابع مشابه
Adjuvant therapy of breast cancer in the elderly: does one size fit all?
6. de Feyter PJ. Percutaneous treatment of saphenous vein bypass graft obstructions: a continuing obstinate problem. 7. Bejarano J. Mechanical protection of cardiac microcirculation during percuta-neous coronary interevntion of saphenous vein grafts. Int J Cardiol. In press. 8. Baim DS, Wahr D, George B, et al. Randomized trial of a distal embolic protection device during percutaneous intervent...
متن کاملAn update on herpes virus infections in graft recipients.
percutaneous coronary and carotid interventions. Curr Control Trials Cardiovasc Med 2001; 2: 286–291 11. Angelini A, Reimers B et al. Cerebral protection during carotid artery stenting. Stroke 2002; 33: 456–461 12. Webb JG, Carere RGC, Virmani R et al. Retrieval and analysis of particulate debris after saphenous vein graft intervention. J Am Col Cardiol 1999; 34: 468–475 13. Baim DS, Wahr D, Ge...
متن کاملRandomized Trial of a Distal Embolic Protection Device During Percutaneous Intervention of Saphenous Vein Aorto-Coronary Bypass Grafts
Background—Stents provide effective treatment for stenotic saphenous venous aorto-coronary bypass grafts, but their placement carries a 20% incidence of procedure-related complications, which potentially are related to the distal embolization of atherosclerotic debris. We report the first multicenter randomized trial to evaluate use of a distal embolic protection device during stenting of such ...
متن کاملRandomized comparison of distal protection with a filter-based catheter and a balloon occlusion and aspiration system during percutaneous intervention of diseased saphenous vein aorto-coronary bypass grafts.
BACKGROUND The high rate of periprocedural complications resulting from atherothrombotic embolization after percutaneous intervention in diseased saphenous vein grafts is reduced by distal microcirculatory protection using a balloon occlusion and aspiration system. Whether filter-based catheters, which offer the inherent advantages of maintained perfusion and ease of use, are as effective for t...
متن کاملA novel filter-based distal embolic protection device for percutaneous intervention of saphenous vein graft lesions: results of the AMEthyst randomized controlled trial.
OBJECTIVES We sought to evaluate the relative safety and efficacy of the novel Interceptor PLUS Coronary Filter System (Medtronic Vascular, Santa Rosa, California) compared with approved embolic-protection devices (e.g., GuardWire, Medtronic Vascular/FilterWire EZ, Boston Scientific, Natick, Massachusetts) during percutaneous coronary intervention (PCI) of degenerative saphenous vein grafts (SV...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Circulation
دوره 106 15 شماره
صفحات -
تاریخ انتشار 2002