Beat-to-beat evaluation of systolic time intervals during bicycle exercise using impedance cardiography.

نویسندگان

  • Takashi Ono
  • Miharu Miyamura
  • Yoshifumi Yasuda
  • Tomonori Ito
  • Toshikazu Saito
  • Toshimichi Ishiguro
  • Makoto Yoshizawa
  • Tomoyuki Yambe
چکیده

In order to elucidate the beat-to-beat changes of the systolic time intervals (STI) during exercise, we proposed new techniques relating to an adaptive filter and detection algorithms for B- and X-points in the impedance cardiograph (ICG). Six male subjects underwent a ramp bicycle exercise up to maximum intensity during which an ECG, ICG and phonocardiogram (PCG) were continuously measured. Following the application of an adaptive filter, the scaled Fourier linear combiner (SFLC), to the first derivative (dZ/dt) of the base impedance (deltaZ) and PCG waveforms, the B- and X-points were automatically determined. For the B-point detection we used three criteria: the zero-crossing point (B(zero)), the 15% response point (B15%) of the negative peak of the dZ/dt (dZ/dt(min)) and a new algorithm (B(new)). The X-point was separately determined by using the ICG and PCG waveforms. It was found that the shape of the dZ/dt waveform directly affected the determination of the B- and X-points. The B-points determined using B(zero) and B15%, criteria were sometimes unstable caused by the location of a notch preceding the dZ/dt(min) compared to the B(new). The time difference between the X-points measured by the ICG and PCG was mostly within +/- 20 milliseconds but statistically significant. Although a wide variation was seen in R-R intervals, the STI were more stable. The relationships between HR and STI from rest to maximal exercise showed a gentle curvilinear relationship. It is suggested that the STI can be obtained precisely on a beat-to-beat basis by using the adaptive filter and detection algorithms for the inflection points of the ICG even during maximum exercise.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Validity of the adaptive filter for accurate measurement of cardiac output in impedance cardiography.

The purpose of this study was to assess the validity of an adaptive filter, the scaled Fourier linear combiner (SFLC), in the impedance cardiography (ICG). Eight healthy males underwent constant-load bicycle exercise at different intensities from unloaded to near maximal intensity. The stroke volume (SV) and cardiac output (Q) measured by ICG at each condition were compared with those by the CO...

متن کامل

Wavelet Based Denoising for Suppression of Motion Artifacts in Impedance Cardiography

Introduction Impedance cardiography is a noninvasive technique for monitoring the changes in the electrical impedance of the thorax z(t), caused by variation in the blood volume during the cardiac cycle [1]. Time derivative of the thoracic impedance is known as the impedance cardiogram (ICG) and it is used for estimating the ventricular ejection time (Tlvet), the negative peak of ICG ((-dz/dt)m...

متن کامل

Head-up-tilt testing in children: new perspectives using beat-to-beat blood-pressure monitoring

The head-up-tilt-test in pediatric patients for the evaluation of syncope shows a sensitivity of 35-85% and often requires pharmacological stimulation in order to improve its diagnostic value. We used a new device for beat-to-beat blood pressure monitoring combined with impedance cardiography in a 12-year-old girl during tilt testing. A seven seconds asystolia was provoked. The haemodynamic par...

متن کامل

Sleep and circadian influences on cardiac autonomic nervous system activity.

To assess the separate contributions of the sleep and circadian systems to changes in cardiac autonomic nervous system (ANS) activity, 12 supine subjects participated in two 26-h constant routines, which were counterbalanced and separated by 1 wk. One routine did not permit sleep, whereas the second allowed the subjects to sleep during their normal sleep phase. Parasympathetic nervous system ac...

متن کامل

Instantaneous measurement of left and right ventricular stroke volume and pressure-volume relationships with an impedance catheter.

The feasibility of using continuous on-line recording of intraventricular electrical impedance to measure ventricular stroke volume was assessed in 12 patients at cardiac catheterization with a multielectrode impedance catheter and a 1.3 kHz measuring current of 4 microA. Stroke volumes determined by electrical impedance were compared with stroke volumes determined by the thermodilution techniq...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Tohoku journal of experimental medicine

دوره 203 1  شماره 

صفحات  -

تاریخ انتشار 2004