Determination of furosemide in whole blood using SPE and GC-EI-MS.
نویسندگان
چکیده
A simple and rapid method was validated to determine furosemide in whole blood. The experimental work was performed so that all validation parameters are considered simultaneously in a one-day assay protocol. A solid-phase extraction procedure using BondElut-LRC Certify columns was used to extract this compound from blood samples, while ketoprofen was used as an internal standard. The extracts were analyzed by gas chromatography-electron ionization-mass spectrometry after on-column derivatization with trimethylanilinium hydroxide (0.2M in methanol). Calibration curves were prepared daily, between 0.10 and 5.00 microg/mL, and the correlation coefficients were above 0.9910. The calculated limits of detection and quantitation were 0.010 and 0.045 microg/mL, respectively. Control samples at low, medium, and high concentrations (0.30, 0.75, and 3.00 microg/mL) of furosemide of an independent source were measured in the same day. Precision and trueness, calculated in terms of relative standard deviation (%), were less than 15% for all concentration levels. The relative recoveries calculated for the three levels of the control samples were 104%, 89%, and 91%, respectively. In general, a sensitive, specific, and reliable procedure has been developed for the determination of furosemide in whole blood samples and was found suitable for the application in postmortem forensic toxicology routine analysis.
منابع مشابه
Determination of Benzo[a]pyrene in Traditional, Industrial and Semiindustrial Breads Using a Modified QuEChERS Extraction, Dispersive SPE and GC-MS and Estimation of its Dietary Intake.
A fast and simple modified QuEChERS extraction method was developed for determination of Benzo[a]pyrene (BaP) in 137 traditional (Sangak), semi-industrial (Sangak) and industrial bread samples using spiked calibration curves by GC/MS. Sample preparation includes extraction of BaP into acetone followed by cleanup with dispersive solid phase extraction. The limit of detection and limit of quantif...
متن کاملDetermination of Benzo[a]pyrene in Traditional, Industrial and Semiindustrial Breads Using a Modified QuEChERS Extraction, Dispersive SPE and GC-MS and Estimation of its Dietary Intake.
A fast and simple modified QuEChERS extraction method was developed for determination of Benzo[a]pyrene (BaP) in 137 traditional (Sangak), semi-industrial (Sangak) and industrial bread samples using spiked calibration curves by GC/MS. Sample preparation includes extraction of BaP into acetone followed by cleanup with dispersive solid phase extraction. The limit of detection and limit of quantif...
متن کاملCombined Determination of 1,4-Dioxane and Nitrosamine Contaminants in Drinking Water Using a Single SPE Cartridge and Concurrent Solvent Recondensation– Large Volume Splitless Injection (CSR-LVSI) With EI GC-MS
Global concern over the carcinogenic potential of 1,4-dioxane and several nitrosamines has resulted in increased interest in the development of more e" cient testing methods for these contaminants in drinking waters. In the U.S., the current methodologies recommended for the analysis of 1,4-dioxane and nitrosamines in drinking waters are Environmental Protection Agency (EPA) Methods 522 and 521...
متن کاملAg-Tetrahydrocannabinol from Whole Blood Using the Zymark RapidTrace with Confirmation and Quantitation by GC-EI-MS
A sensitive, reliable, and automated solid-phase extraction (SPE) method was developed for the simultaneous extraction, confirmation, and quantitation of Ag-tetrahydrocannabinol (THC) and 11-nor-9-carboxy-A%tetrahydrocannabinol (THCCOOH) from whole blood. The extraction was performed on the Zymark RapidTrace SPF Workstation with a reduced solvent volume SPE copolymer cartridge. Quantitative ana...
متن کاملCombined Determination of 1,4-Dioxane and Nitrosamine Contaminants in Drinking Water Using SPE and CSR-LVSI GC-MS
Global concern over the carcinogenic potential of 1,4-dioxane and several nitrosamines has resulted in increased interest in the development of more efficient testing methods for these contaminants in drinking waters. In the U.S., the current methodologies recommended for the analysis of 1,4-dioxane and nitrosamines in drinking waters are Environmental Protection Agency (EPA) Methods 522 and 52...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of analytical toxicology
دوره 29 5 شماره
صفحات -
تاریخ انتشار 2005