Multiply Charged Redox-Active Oligomers in the Gas Phase: Electrolytic Electrospray Ionization Mass Spectrometry of Metallocenes

نویسندگان

  • Tracy Donovan McCarley
  • Michael W. Lufaso
  • Larry S. Curtin
  • Robin L. McCarley
چکیده

The inherent constant-current electrolytic (CCE) nature of electrospray ionization mass spectrometry (ESIMS) is used to study a variety of neutral metallocenes, including oligomeric metallocenes. ESI mass spectra that display the doubly charged ion of certain biferrocenes (M2+) can be readily obtained by careful manipulation of solution conditions and structure of the biferrocene. The intensity ratio of M2+ to the singly charged (M+) biferrocene, IM2+/IM+, is strongly affected by the formal potentials of the two ferrocene sites (E1 and E2), the distance between the two redox centers, the analyte infusion (flow) rate, and concentration of the neutral metallocene. For a biferrocene whose redox centers are well separated and E1 . E2, lower analyte concentrations and flow rates yield a higher IM2+/IM+, but the maximum achievable value is only 0.04. However, if the redox centers are physically well separated and E1 = E2, values of up to 0.3 for IM2+/IM+ are attainable; through use of probability theory and IM2+/IM+, the electrochemical potential at the electrospray needle can be calculated. Multiply charged ions for several oligo(ferrocenyldimethylsilanes) are observed when electrolytecontaining solutions of the oligo(ferrocenyldimethylsilanes) are directly infused into the ESI sourcesin the case of the octa(ferrocenyldimethylsilane), the M4+ species is observed. To our knowledge, this is the first demonstration of ions with greater than two charges formed by electrolytic ESI-MS.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Electrospray ionization high-resolution ion mobility spectrometry-mass spectrometry.

A hybrid atmospheric pressure ion mobility spectrometer is described which exhibits resolving power approaching the diffusion limit for singly and multiply charged ions (over 200 for the most favorable case). Using an electrospray ionization source and a downstream quadrupole mass spectrometer with electron multiplier as detector, this ESI-IMS-MS instrument demonstrates the potential of IMS for...

متن کامل

Recent developments in the ion/ion chemistry of high-mass multiply charged ions.

The ability to form multiply charged high-mass ions in the gas-phase, most notably via electrospray ionization (ESI), has allowed the study of many different combinations of positively and negatively charged ions. The charged products are directly amenable to study with mass spectrometry. Ion/ion reactions have proved to be "universal" in the sense that the high exothermicities and large rate c...

متن کامل

Ultrasonication-assisted spray ionization mass spectrometry for the analysis of biomolecules in solution.

In this paper, we describe a novel technique--ultrasonication-assisted spray ionization (UASI)--for the generation of singly charged and multiply charged gas-phase ions of biomolecules (e.g., amino acids, peptides, and proteins) from solution; this method employs a low-frequency ultrasonicator (ca. 40 kHz) in place of the high electric field required for electrospray ionization. When a capillar...

متن کامل

Protein folding mechanisms studied by time-resolved electrospray mass spectrometry.

Mass spectrometry (MS) owes its remarkable rise as a bioanalytical tool to the development of two “soft” ionization techniques: matrix-assisted laser desorption/ ionization (MALDI) (1,2) and electrospray ionization (ESI) (3). The salient feature of soft ionization is that a wide range of analytes, from small metabolites to very large biomolecular systems, can be transferred intact into the gas ...

متن کامل

Photoelectron spectroscopy of multiply charged anions.

Multiply charged anions (MCAs) are common in condensed phases but are challenging to study in the gas phase. An experimental technique, coupling photoelectron spectroscopy (PES) with electrospray ionization (ESI), has been developed to investigate the properties of free MCAs in the gas phase. This article reviews the principles of this technique and some initial findings about the intrinsic pro...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1998