Rapid detection of neonatal hypoglycaemia

ثبت نشده
چکیده

The use of Dextrostix Reflectance Meter (DRM)* to measure blood glucose has been reported recently. The method has proved to be simnple, rapid, and accurate, and to correlate well with various reference methods (Mazzaferri et al., 1970; Jarret, Keen, and Hardwick, 1970; Schersten, 1971; Deckert and Futtrup, 1971). The handiness of the DRM seemed to make it an excellent tool in the diagnosis of neonatal hypoglycaemia, and for this reason the DRM system was evaluated in the newborn under conditions of daily nursery use.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rapid detection of neonatal hypoglycaemia

The use of Dextrostix Reflectance Meter (DRM)* to measure blood glucose has been reported recently. The method has proved to be simnple, rapid, and accurate, and to correlate well with various reference methods (Mazzaferri et al., 1970; Jarret, Keen, and Hardwick, 1970; Schersten, 1971; Deckert and Futtrup, 1971). The handiness of the DRM seemed to make it an excellent tool in the diagnosis of ...

متن کامل

Death within the first 24 hours of admission among newborn infants aged less than 24 hours in a Nigerian Special Care Baby Unit: Role of significant hypothermia and hypoglycaemia

Background: Neonatal deaths mostly occur within the first one week and first 24 hours of life from a variety of conditions. Objective: To examine the role of significant hypothermia and hypoglycaemia, in addition to some other factors, in neonatal mortality occurring within the first 24 hours of admission.Methods: A prospective study of newborn infants hospitalized within the first 24 hours of ...

متن کامل

Comparison of two cotside methods for the detection of hypoglycaemia among neonates in Nepal.

AIMS To compare two cotside methods of blood glucose measurement (HemoCue and Reflolux II) against a standard laboratory method for the detection of neonatal hypoglycaemia in a developing country maternity hospital where hypoglycaemia is common. METHODS 94 newborn infants and 75 of their mothers had blood glucose assessed on the same venous sample using three different methods in the Special ...

متن کامل

Quantitative Bacterial Micro-Assay for Rapid Diagnosis of Galactosemia: Application in Galactosemia Neonatal Screening

In the present study a new economic and rapid bacterial micro-assay for simultaneous detection and quantitative measurement of serum galactose was developed. Analysis of the standard curve showed a linearity range for galactose from 2 mg/dL to 180 mg/dL with a regression equation of Y = 0.013X ? 0.083; R² = 0.962. The advantage of the method is its ability to measure serum galactose quantitativ...

متن کامل

Preventive treatment of neonatal hypoglycaemia in infants of insulin dependent diabetic mothers.

Neonatal hypoglycaemia (blood glucose smaller than 20 mg/100 ml) occurred in the first 6 hours of life in 25 of 34 infants born to diabetic mothers receiving insulin. Despite severe hypoglycaemia (blood glucose smaller than 10 mg/100 ml) in 17, clinical features of hypoglycaemia were absent in all but 2. Hypoglycaemia was not related either to the level of plasma insulin in cord blood, determin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006