An Intra-comparison between Geant4-dna and a Variety of Monte Carlo Codes 2
نویسندگان
چکیده
20 Modelling the radio-induced effects in biological medium requires accurate physics models to 21 describe in detail the main physical interactions induced by all the charged particles present in 22 the irradiated medium (secondary as well as primary ones). These interactions include 23 inelastic events like ionization and excitation processes as well as elastic scattering, the latter 24 being the most important process in the low-energy regime. To check the accuracy of the 25 2 theoretical models recently implemented into the Geant4 toolkit for modelling the electron 26 slowing-down in liquid water, the simulation of electron Dose Point Kernels remains the 27 preferential test. In this work, normalized radial profiles of deposited energy at a distance 28 from emissions point sources are then computed in liquid water by using the very low energy 29 " Geant4-DNA " physics processes available in the Geant4 toolkit. We here report an extensive 30 comparison with profiles obtained by a large selection of existing and well-documented 31
منابع مشابه
Evaluation of cellular S-value of auger electrons emitting 111In radionuclide by Geant4 and its comparison with MCNP5 Monte Carlo codes and MIRD published data
Introduction: Now day Ionizing radiation has found increasing applications in cancer treatment. However, in the treatment different kinds and size of tumors especially metastatic and small size tumors, conventional methods of external radiation therapy are not common. In radionuclide therapy, the use of monoclonal antibodies has made it possible to achieve maximum dose to small size tumor and m...
متن کاملCellular S-value of beta emitter radionuclide’s determined using Geant4 Monte Carlo toolbox, comparison to MIRD S-values
Introduction: Spatial dose distribution around the radionuclides sources is required for optimized treatment planning in radioimmunotherapy. At present, the main source of data for cellular dosimetry is the s-values provided by MIRD. However, the MIRD s-values have been calculated based on analytical formula in which no electrons straggling is taken to account. In this study, we used Geant4-DNA...
متن کاملDose point kernels in liquid water: an intra-comparison between GEANT4-DNA and a variety of Monte Carlo codes.
Modeling the radio-induced effects in biological medium still requires accurate physics models to describe the interactions induced by all the charged particles present in the irradiated medium in detail. These interactions include inelastic as well as elastic processes. To check the accuracy of the very low energy models recently implemented into the GEANT4 toolkit for modeling the electron sl...
متن کاملComparison of ScintSim1 and Geant4 Monte Carlo simulation codes for optical photon transport in thick segmented scintillator arrays
Introduction: Arrays of segmented scintillation crystals are useful in megavoltage x-ray imaging detectors for image-guided radiotherapy. Most previous theoretical studies on these detectors have modelled only ionizing-radiation transport. Scintillation light also affects detector performance. ScintSim1, our previously reported optical Monte Carlo code for such detector...
متن کاملRadioiodine (131-I) treatment for Graves’ disease: Geant4 Monte Carlo simulation for patient personalized dose estimation
Background: Reliable estimation of radiation-absorbed dose is necessary to evaluate the benefits and the risks of radiopharmaceuticals used for diagnostic or therapeutic purposes in nuclear medicine. Materiel and Methods: This study included 47 patients treated with iodine-131 for Graves’ disease. A comparative study between Geant4 Monte Carlo simulation and MIRD formalism was carried out to ev...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2013