Quench Performance and Field Quality of DX Dipoles for RHIC
نویسندگان
چکیده
DX dipoles, with an aperture of 18 cm, are located on each side of the six intersection regions of RHIC. All DX dipoles were tested at 4.35 K for quench performance, and trained successfully to at least a 10% margin above the operating field (4.3 T at 6.6 kA). Field quality in these dipoles was measured at room temperature and at 4.35 K using a rotating coil system. The measured harmonics were corrected for offsets of the measuring coil from the magnetic axis, determined by a variety of techniques. All harmonics were found to be within acceptable limits.
منابع مشابه
Real-world Sorting of Rhic Superconducting Magnets
During the seven-year construction of the Relativistic Heavy Ion Collider (RHIC), more than 1700 superconducting dipoles, quadrupoles, sextupoles, and multi-layer correctors have been constructed and installed. These magnets have been sorted at several production stages to optimize their performance and reliability. For arc magnets, priorities have been put first on quench performance and opera...
متن کاملChange in Field Harmonics after Quench and Thermal Cycles in Superconducting Magnets*
A change in field harmonics after quench and thermal cycles has been observed in superconducting magnets for the Relativistic Heavy Ion Collider (RHIC). This paper presents the results of a systematic investigation of this effect in a number of RHIC dipole and quadrupole magnets. These changes in field harmonics may limit the ultimate field quality and its reproducibility in superconducting mag...
متن کاملRHIC IR Quadrupoles and Field Quality State of the Art in Superconducting Accelerator Magnets
The interaction region (IR) quadrupoles [1] for the Relativistic Heavy Ion Collider (RHIC) [2] are the best field quality superconducting magnets ever built for any major accelerator. This field quality is primarily achieved with the help of eight tuning shims [3] that remove the residual errors from a magnet after it is built and tested. These shims overcome the limitations from the typical to...
متن کاملField Quality Control through the Production Phase of Rhic Arc Dipoles
The field quality in the arc dipoles built thus far for the Relativistic Heavy Ion Collider (RHIC) not only meets machine requirement& but is significantly better than that expected from scaling laws based on previous large scale superconducting magnet production for particle accelerators. In this paper we describe th& evolution of the present cross section and the design philosophy that has le...
متن کاملField Quality Analysis as a Tool to Monitor Magnet Production
Field harmonics offer a powerful tool to examine the mechanical structure of accelerator magnets. A large deviation from the nominal values suggests a mechanical defect. Magnets with such defects are likely to have a poor quench performance. Similarly, a trend suggests a wear in tooling or a gradual change in the magnet assembly or in the size of a component. This paper presents the use of the ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -