Compact solid-state neutral particle analyzer in current mode.

نویسندگان

  • Y B Zhu
  • A Bortolon
  • W W Heidbrink
  • S L Celle
  • A L Roquemore
چکیده

Solid state neutral particle analyzer (ssNPA) arrays are operated in current mode on the DIII-D tokamak and the National Spherical Torus Experiment (NSTX). Compared with conventional pulse-counting NPAs, current-mode operation sacrifices energy resolution to obtain economical, high-bandwidth, pitch-angle resolved measurements. With the success from a new three-channel near-vertical-view current mode ssNPA on DIII-D, the apertures on an existing array on NSTX were expanded to increase the particle influx. The sightlines of both arrays intersect heating beams, enabling both active and passive charge exchange measurements. The spatial resolution at beam intersection is typically 5 cm on both devices. Directly deposited ultra-thin foils on the detector surface block stray photons below the energy of 1 keV and also set low energy threshold about 25 keV for deuterium particle detection. Oscillations in neutral flux produced by high frequency magnetohydrodynamics (MHD) instabilities are readily detected.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Bismuth Pyromangenate: Hydrothermal and Solid State Synthesis, Characterization and Optical Properties

Bi2Mn2O7 nano-powders were synthesized via a stoichiometric 1:1 Bi:Mn molar ratio hydrothermal method at 180 °C for 48 h in a 1M NaOH aqueous solution; and solid state method, using Bi(NO3)3.5H2O and MnO2 as raw materials. The synthesized materials were characterized by powder X-ray diffraction (PXRD) technique. Also, the rietveld analysis was done in FullProf in profile matching mode. It was f...

متن کامل

Design of a retarding potential grid system for a neutral particle analyzer.

The ion energy distribution in a magnetically confined plasma can be inferred from charge exchange neutral particles. On the Madison Symmetric Torus (MST), deuterium neutrals are measured by the Florida A&M University compact neutral particle analyzer (CNPA) and the advanced neutral particle analyzer (ANPA). The CNPA energy range covers the bulk deuterium ions to the beginning of the fast ion t...

متن کامل

A Method for Ion Distribution Function Evaluation Using Escaping Neutral Atom Kinetic Energy Samples

A reliable method to evaluate the probability density function for escaping atom kinetic energies is required for the analysis of neutral particle diagnostic data used to study the fast ion distribution function in fusion plasmas. Digital processing of solid state detector signals is proposed in this paper as an improvement of the simple histogram approach. Probability density function for kine...

متن کامل

Rotation Operator Vs Particle Creation in a Curved Space Time

Taking into account a neutral massive scalar field minimally coupled to gravity, in a Robertson-Walker metric, it is shown that when the final state is connected with the initial one by means of a Bogoliubov transformation, which does not include the single-mode rotation operator, the mean value of created particles is conserved. When the rotation operator is considered, it is still possible to...

متن کامل

Sliding-Mode Control of the DC-DC Ćuk Converter in Discontinuous Conduction Mode

In this paper, a novel approach for two-loop control of the DC-DC Ćuk converter in discontinuousconduction mode is presented using a sliding mode controller. The proposed controller can regulatethe output of the converter in a wide range of input voltage and load resistance. Controllerparameters are selected using PSO algorithms. In order to verify the accuracy and efficiency of thedeveloped sl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Review of scientific instruments

دوره 83 10  شماره 

صفحات  -

تاریخ انتشار 2012