چکیده

Cardiomyopathies are the most common type of cardiac diseases in cats. Although some normal echocardiographic values for cats have been published, there are variations based on breeds and gender. The objective of this study is to determine normal reference values for M-mode echocardiographic parameters in nonsedated healthy adult Van cats and to compare those values with data reported for nonsedated healthy cats of other breeds. A total of 40 clinically healthy Van cats of both sexes belonging to the Van Cat Research and Application Center of Yuzuncu Yil University were used. Body weight (BW) and 16 M-mode echocardiographic variables were measured in 40 healthy Van cats. The effect of gender and age on each echocardiographic parameter was analyzed and the relationship between BW and each parameter investigated. There was a significant relationship between gender and left atrial dimension during ventricular systole (LAD) and aortic root dimension at end-diastole (AOD) as well as between BW and interventricular septal thickness at end-diastole (IVSd) and end-systole (IVSs), left ventricular internal dimension at end-diastole (LVIDd), left ventricular posterior wall thickness at end-diastole (LVPWd), LAD, AOD, the left ventricular end diastolic volume (EDV) and the stroke volume (SV). A relationship between age and the SV parameter alone was also established. This present study is the first work on cardiac reference values for Van cats highlighting the differences in some M-mode echocardiographic parameters of healthy adult Van cats and other cat breeds, which should be considered when interpreting echocardiographic findings, in order to draw the correct conclusions regarding cardiac health.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Echocardiographic Measurement of Systolic Time Intervals in Healthy Great Dane Dogs

Objective- to determine the range of systolic times intervals using Pulsed-wave Doppler and m-mode echocardiography in normal, healthy Great Dane dogs. Design- Descriptive study. Animals- Thirty healthy Great Dane dogs. Procedures- This study examined 30 clinically healthy Great Dane dogs by the twodimensional, M-mode and Pulsed-wave Doppler echocardiography. The dogs were awake and unsedated. ...

متن کامل

Echocardiographic parameters in healthy young adult Sphynx cats.

The objective of this retrospective study is to determine normal reference values for 2-Dimension (2D) and Motion-mode (M-mode) echocardiographic parameters in nonsedated healthy young adult Sphynx cats and to compare them to those of the domestic shorthair (DSH). 131 Sphynx cats underwent cardiac screening prior to breeding. The control group consisted of 30 healthy adult domestic cats. A comp...

متن کامل

Reference values of M-mode echocardiographic parameters and indices in conscious Labrador Retriever dogs

Breed-wise standard echocardiographic values in dogs have been reported as there is variation in body and chest conformation which limits the application of data of one breed for other breed. Labrador Retrievers being originated from hunting dogs, might have different echocardiographic values from standard normal range of other dog breeds. So, the present study was aimed to determine the M-mode...

متن کامل

Normal Echocardiographic Findings in Healthy Pigeons

Objective- The purpose of this study was to investigate the feasibility of performing echocardiography in apparently healthy pigeons, and measurement of the quantitative cardiac indices using B-mode and Doppler techniques. Design- Experimental study Animals- Ten apparently healthy pigeons Procedures- Echocardi...

متن کامل

Study of Cardiac Parameters by Pulsed Wave Doppler Echocardiography in Normal Healthy Markhoz Goat

Objective- The aim of this study was to test the repeatability, the variability, and to establish the reference values of PW measurements in healthy Markhoz goats.Design- Retrospective study.Animals- 20 female Markhoz goats.Procedure- Using a standardized PW Doppler echocardiographic protocol, 20healthy adult unsedated female Markhoz goats were investigated three times at one-...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Japanese journal of veterinary research

دوره 62 1-2  شماره 

صفحات  -

تاریخ انتشار 2014