Estimation of Space Air Change Rates and CO2 Generation Rates for Mechanically-Ventilated Buildings
نویسندگان
چکیده
It is well known that people spend 80-90% of their life time indoors. At the same time, pollution levels of indoors can be much higher than outdoor levels. Not surprisingly, the term ‘sick building syndrome’ (SBS) has been used to describe situations where occupants experience acute health and comfort effects that are related to poor air in buildings (Clements-Croome, 2000). It is an increasingly common health problem which has been acknowledged as a recognizable disease by the World Health Organization (Redlich et al., 1997, Akimenko et al., 1986). Since its recognition in 1986, many efforts have been put to try to identify the causes to eliminate SBS. The causes may involve various factors. Mainly, it is thought to be a direct outcome of poor indoor air quality (IAQ) (Clements-Croome, 2004). In most cases ventilation system is found to be at the heart of the problem as well as high carbon dioxide (CO2) levels (Redlich et al., 1997). Since 70’s energy crisis, buildings have been tried to build with tight envelopes and highly rely on mechanical ventilation so as to reduce energy cost. Due to tight envelopes, a big portion of energy contributes to ventilation. In most cases SBS occurs in mechanically-ventilated and commercial buildings, although it may occur in other buildings such as apartment buildings. It has been estimated that up to 30% of refurbished buildings and a significant number of new buildings suffer from SBS (Sykes, 1988). However, the solutions to SBS are difficult to implement by the complexity of ventilation system and the competing needs of energy saving. Hence the issue about ventilation efficiency is getting more and more people’s attention. It is useful to evaluate ventilation in order to assess IAQ and energy cost. A number of techniques are available to perform such evaluations. Among them, the measurement and analysis of CO2 concentrations to evaluate specific aspects of IAQ and ventilation is most emphasized. CO2 is a common air constituent but it may cause some heath problems when its concentration level is very high. Normally CO2 is not considered as a causal factor in human health responses. However, in recent literalities, it has been reported that there is a statistically significant association of mucous membrane (dry eyes, sore throat, nose congestion, sneezing) and lower respiratory related symptoms (tight chest, short breath, cough and wheeze) with increasing CO2 levels above outdoor levels (Erdmann & Apte,
منابع مشابه
Study of Dioxide Carbon Concentration and Indoor Air Quality in Some Buildings in the Equatorial Region of Cameroon (Yaounde)
Background and purpose: Elevated CO2 rate in a building affect the health of occupant. This document presents results of an experimental analysis conducted in 50 offices located in 12 buildings with different layer in Cameroon (Yaounde). This study took place in 2012, during the dry and the rainy seasons. The main goal is to show the influence of the building structure, the ventilation and the ...
متن کاملAir Quality and Emission Measurement Methodology
Reliable measurements of air quality and emissions at large livestock buildings with inherently large spatial and temporal variations of pollutant concentrations are relatively difficult and expensive. Appropriate methodologies for such measurements are not readily apparent and techniques and strategies vary widely. Several important technical issues need to be addressed by an air pollutant emi...
متن کاملReview and Extension of CO2-Based Methods to Determine Ventilation Rates with Application to School Classrooms
The ventilation rate (VR) is a key parameter affecting indoor environmental quality (IEQ) and the energy consumption of buildings. This paper reviews the use of CO₂ as a "natural" tracer gas for estimating VRs, focusing on applications in school classrooms. It provides details and guidance for the steady-state, build-up, decay and transient mass balance methods. An extension to the build-up met...
متن کاملComparison of environment and mice in static and mechanically ventilated isolator cages with different air velocities and ventilation designs.
The purpose of this study was to compare environmental conditions and mice in cages with four different mechanical ventilation designs and a static isolator cage. Environmental conditions (air velocity, temperature, relative humidity, bedding weight change, airborne dust, NH3, and CO2) were compared for each cage type (n = 5 per cage). Bedding type was chipped hardwood. Mouse response in each c...
متن کاملPredictive model for CO2 generation and decay in building envelopes
Understanding carbon dioxide generation and decay patterns in buildings with high occupancy levels is useful to identify their indoor air quality, air change rates, percent fresh air makeup, occupancy pattern, and how a variable air volume system to off-set undesirable CO2 level can be modulated. A mathematical model governing the generation and decay of CO2 in building envelopes with forced ve...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -