Using ultrasound to assess the thickness of the transversus abdominis in a sling exercise
نویسندگان
چکیده
BACKGROUND Activation of the deep stabilizing trunk muscle transversus abdominis (TrA) is important for trunk stabilization and spine stability. Sling exercises are used for the activation of trunk muscles, therefore we determined the thickness of the TrA in a standardized sling exercise in comparison to rest and abdominal press. Furthermore we propose a standardized measurement method, which can be used to compare relative muscle thickness levels in different exercises. METHODS The main objective of the study was to assess and to compare the thickness of the TrA during different conditions; resting condition, sling exercise condition (non-voluntary contraction), and abdominal press condition (voluntary contraction) using a non-invasive ultrasound-based measurement method. Ultrasound measurement (USM; 8.9 MHz, B-mode) was employed to measure the thickness of the TrA in twenty healthy volunteers (13 m, 7 f), each one measured three times with breaks of 48 h. On each measurement day, the subjects were measured on three different conditions: resting condition (RC), sling condition (SC), and abdominal press condition (APC). The USM images were analyzed using a custom-made MatLab script, to determine the thickness of the TrA. RESULTS A two-way repeated-measurements ANOVA was performed with a significant effect of the factor condition [F(2,38) = 47.82, p < 0.0001, η(2) = 0.72], no significant effect of the factor time [F(2.38) = 2.45, p = 0.1, η(2) = 0.11], and no significant interaction effect [F(4,76) = 0.315, p = 0.867, η(2) = 0.02]. Statistically corrected post-hoc t-tests revealed significant differences in TrA thickness showing that RC < SC (p < 0.001; η(2) = 0.19; d = 0.96), SC < APC (p < 0.0001; η(2) = 0.23; d = 1.10), RC < APC (p < 0.0001; η(2) = 0.53; d = 2.11). As for the test-retest reliability the intra-class correlation coefficient (ICC) yielded a value of 0.71, 0.54, and 0.29, on the conditions RC, SC, and APC, respectively. CONCLUSIONS We showed that the investigated sling exercise can be used to significantly increase the TrA thickness, and that the TrA thickness was significantly different on the three conditions (RC, SC, APC) using the ultrasound-based method.
منابع مشابه
Effect of core muscle thickness and static or dynamic balance on prone bridge exercise with sling by shoulder joint angle in healthy adults
[Purpose] To date, core muscle activity detected using ultrasonography during prone bridge exercises has not been reported. Here we investigated the effects of core muscle thickness and balance on sling exercise efficacy by shoulder joint angle in healthy individuals. [Subjects and Methods] Forty-three healthy university students were enrolled in this study. Ultrasonography thickness of externa...
متن کاملEffects of Bridging Exercise on Different Support Surfaces on the Transverse Abdominis
[Purpose] The purpose of this study was to identify the effects of bridging exercise on different support surfaces on the thickness of the musculus transversus abdominis and lower extremity muscle activities. [Subjects] Thirty-five students of H University. [Methods] The experimental group (n=18) performed bridging exercise on the sling support surface, and the control group (n=17) performed br...
متن کاملتأثیر تمرینهای کنترل حرکت در برابر تمرینهای متداول بر ضخامت عضلات ثباتدهندهی موضعی کمر: مطالعهی تصادفی کنترل شده در افراد مبتلا به کمردرد مزمن
Background and Objective: In recent years, management of patients with chronic low back pain has been focused on transversus abdominis and multifidus muscles. The evidences have demonstrated dysfunction of these muscles in these patients. This study was aimed to compare the usefulness of motor-control exercises and conventional exercises on the lumbar local stabilizing muscles thickness, activi...
متن کاملReliability of ultrasound imaging of the transversus abdominis muscle in asymptomatic subjects
[Purpose] The purpose of this study was to assess intra-rater and inter-rater procedural reliability of ultrasound imaging measurements of transversus abdominis thickness. [Subjects] Thirty therapists who attended the B Hospital in Hwaseong participated in the study. [Methods] Two examiners assessed transverse abdominis thickness at rest and during contraction. Intra-class correlation coefficie...
متن کاملThe relationship between EMG and change in thickness of transversus abdominis.
OBJECTIVE To investigate the relationship between changes in thickness and EMG activity in the transversus abdominis muscle of healthy subjects and the reliability of ultrasound measurements using different modes and transducers. DESIGN Convenience sampling. BACKGROUND Chronic low back pain is associated with transversus abdominis dysfunction but EMG studies of this muscle are restricted to...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 16 شماره
صفحات -
تاریخ انتشار 2015