Haemodynamic effects and outcome analysis of hypotensive extradural anaesthesia in controlled hypertensive patients undergoing total hip arthroplasty.
نویسندگان
چکیده
We have examined the safety of induced hypotension produced by extradural anaesthesia in patients with medically controlled hypertension. The haemodynamic response to induced hypotension was assessed in 38 non-hypertensive and 31 controlled hypertensive patients. All received extradural anaesthesia to T4 or above which decreased mean arterial pressure to 52 mm Hg and 55 mm Hg in normotensive and hypertensive patients, respectively. Cardiac output (thermodilution) was maintained by low dose i.v. infusions of adrenaline (1-5 micrograms min-1). No differences in the haemodynamic response to induced hypotension were observed in hypertensive patients. Data were collected also from 987 consecutive patients (353 hypertensive and 634 non-hypertensive) undergoing total hip replacement. Patients with hypertension were significantly older (68 vs 60 yr; P less than 0.001) and had greater ASA ratings (P less than 0.001). The smallest recorded systolic pressures were reduced more in patients with hypertension (57% vs 52%, respectively; P less than 0.001). The mean duration of maintained intraoperative hypotension (100 and 98 min) and estimated intraoperative blood loss (278 vs 281 ml) were similar in each group. After operation, two patients developed myocardial infarctions. None developed acute renal failure or stroke. There were three deaths; one of a patient who had hypertension. This suggests that induced hypotension with extradural anaesthesia is a safe technique for patients with medically controlled hypertension undergoing total hip arthroplasty.
منابع مشابه
Effect of i.v. low-dose adrenaline and phenylephrine infusions on plasma concentrations of bupivacaine after lumbar extradural anaesthesia in elderly patients.
Thirty patients undergoing primary total hip replacement under lumbar extradural anaesthesia with 0.75% bupivacaine 25 ml were allocated randomly to receive either low-dose adrenaline or phenylephrine infusions i.v. throughout surgery. Haemodynamic measurements and arterial blood samples were obtained before the extradural injection and at 10, 20, 30, 40, 50, 60 and 90 min thereafter. Peak arte...
متن کاملRole of extradural and of general anaesthesia in fibrinolysis and coagulation after total hip replacement.
Thirty patients undergoing total hip replacement were randomly allocated to one of two groups. One group (n = 14) received extradural anaesthesia with 0.5% bupivacaine with adrenaline continued into the postoperative period (24 h) for pain relief. The other group (n = 16) received general anaesthesia with controlled ventilation, using nitrous oxide in oxygen and fentanyl i.v. Following surgery ...
متن کاملExtradural anaesthesia in patients with previous lumbar spine surgery.
We studied prospectively 1381 patients undergoing extradural anaesthesia for total hip or total knee replacement, to determine if extradural anaesthesia can be performed reliably in patients who have had previous lumbar spine surgery. Fifty-two of the 57 patients (91.2%) who had undergone lumbar spine surgery received a successful extradural anaesthetic, and 1307 of 1324 patients without previo...
متن کاملStaphylococcus aureus Colonization in Patients Undergoing Total Hip or Knee Arthroplasty and Costeffectiveness of Decolonization Programme
Background: Periprosthetic joint infection is a devastating complication of total joint arthroplasty. It seems that thepatient’s skin, nose, throat, and urine are important sites for microbial colonization. Colonization with staphylococcusaureus, especially methicillin resistant increases the risk of periprosthetic joint infection. The aim of this study was toassess the prevalence of staphyloco...
متن کاملGoal-directed haemodynamic therapy during elective total hip arthroplasty under regional anaesthesia
INTRODUCTION Total hip replacement is one of the most commonly performed major orthopaedic operations. Goal-directed therapy (GDT) using haemodynamic monitoring has previously demonstrated outcome benefits in high-risk surgical patients under general anaesthesia. GDT has never been formally assessed during regional anaesthesia. METHODS Patients undergoing total hip replacement while under reg...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- British journal of anaesthesia
دوره 67 1 شماره
صفحات -
تاریخ انتشار 1991