Adaptive optics scanning laser ophthalmoscope-based microperimetry.

نویسندگان

  • William S Tuten
  • Pavan Tiruveedhula
  • Austin Roorda
چکیده

PURPOSE To develop and test the application of an adaptive optics scanning laser ophthalmoscope (AOSLO) with eye tracking for high-resolution microperimetric testing. METHODS An AOSLO was used to conduct simultaneous high-resolution retinal imaging and visual function testing in six normal subjects. Visual sensitivity was measured at test locations between the fovea and 5.0° eccentricity via an increment threshold approach using a 40-trial, yes-no adaptive Bayesian staircase procedure (QUEST). A high-speed eye tracking algorithm enabled real-time video stabilization and the delivery of diffraction-limited Goldmann I-sized stimuli (diameter = 6.5 arc min = ∼32 μm; λ = 680 nm) to targeted retinal loci for 200 ms. Test locations were selected either manually by the examiner or automatically using Fourier-based image registration. Cone spacing was assessed at each test location and sensitivity was plotted against retinal eccentricity. Finally, a 4.2 arc min stimulus was used to probe the angioscotoma associated with a blood vessel located at 2.5° eccentricity. RESULTS Visual sensitivity decreases with eccentricity at a rate of -1.32 dB/deg (R = 0.60). The vertical and horizontal errors of the targeted stimulus delivery algorithm averaged 0.81 and 0.89 arc min (∼4 μm), respectively. Based on a predetermined exclusion criterion, the stimulus was successfully delivered to its targeted location in 90.1% of all trials. Automated recovery of test locations afforded the repeat testing of the same set of cones over a period of 3 months. Thresholds measured over a parafoveal blood vessel were 1.96 times higher (p < 0.05; one-tailed t-test) than those measured in directly adjacent retina. CONCLUSIONS AOSLO-based microperimetry has the potential to test visual sensitivity with fine retinotopic precision. Automated recovery of previously tested locations allows these measures to be tracked longitudinally. This approach can be implemented by researchers interested in establishing the functional correlates of photoreceptor mosaic structure in patients with retinal disease.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Structure-functional correlation using adaptive optics, OCT, and microperimetry in a case of occult macular dystrophy.

We report retinal functional and structural changes of a 40-year-old man diagnosed with occult macular dystrophy. Comprehensive ophthalmological evaluation was performed, followed by spectral-domain optical coherence tomography (SD-OC - Heidelberg) and image acquisition using an adaptive optics (AO) camera (RTX1, Imagine Eyes) for photoreceptor density analysis. Functional tests included full-f...

متن کامل

Gaze-contingent display for retinal function testing by scanning laser ophthalmoscope.

To overcome the inconvenience and imprecision of conventional software performing microperimetry with the scanning laser ophthalmoscope (SLO) in clinical settings, we developed a "smart microperimetry" program. It takes advantage of modern computer technology, especially processing speed and high rate of data transfer. It allows continuous on-line processing of the image of the retina and insta...

متن کامل

Dual electro-optical modulator polarimeter based on adaptive optics scanning laser ophthalmoscope

We constructed a high speed and high-resolution Stokes vector retinal imaging polarimeter with dual electro-optical modulators based on adaptive optics scanning laser ophthalmoscope. By varying the voltages on the EO crystals line by line, we were able to measure over 500,000 Stokes vectors per second. We used this system in three human subjects demonstrating the capability of the system to be ...

متن کامل

Large-field-of-view, modular, stabilized, adaptive-optics-based scanning laser ophthalmoscope.

We describe the design and performance of an adaptive optics retinal imager that is optimized for use during dynamic correction for eye movements. The system incorporates a retinal tracker and stabilizer, a wide-field line scan scanning laser ophthalmoscope (SLO), and a high-resolution microelectromechanical-systems-based adaptive optics SLO. The detection system incorporates selection and posi...

متن کامل

Observation of cone and rod photoreceptors in normal subjects and patients using a new generation adaptive optics scanning laser ophthalmoscope

We demonstrate the capability of a new generation adaptive optics scanning laser ophthalmoscope (AOSLO) to resolve cones and rods in normal subjects, and confirm our findings by comparing cone and rod spacing with published histology measurements. Cone and rod spacing measurements are also performed on AOSLO images from two different diseased eyes, one affected by achromatopsia and the other by...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Optometry and vision science : official publication of the American Academy of Optometry

دوره 89 5  شماره 

صفحات  -

تاریخ انتشار 2012