Analysis of charges and complications of permanent pacemaker implantation in the cardiac catheterization laboratory versus the operating room.
نویسندگان
چکیده
During the last two decades, an increasing number of permanent pacemakers have been implanted outside of the operating room (OR) by nonsurgeons. Previous investigators have demonstrated that pacemakers can be safely implanted in the cardiac catheterization laboratory with no increase in complications or infections. This is the first study of its kind to simultaneously evaluate cost, length of hospitalization, and complications between pacemakers implanted in the OR by surgeons with those implanted in the catheterization laboratory by an electrophysiologist. A total of 254 consecutive pacemaker implants were analyzed over a 2-year period. The OR group consisted of 122 patients with a mean age of 64 +/- 21 years versus 132 patients in the catheterization laboratory group with a mean age of 65 +/- 17 years. The indication and type of pacemaker implanted were similar among both groups with 78% of OR patients and 73% of catheterization laboratory patients receiving dual chamber devices. The average cost for pacemaker implantation in our study was significantly higher in the OR group $5,464 +/- $1,670 versus $2,682 +/- $8 for the catheterization laboratory group (P < 0.001). There was a reduction in preimplant days in the catheterization laboratory group 3.16 +/- 12.40 days versus 5.65 +/- 9.54 days in the OR group (P < 0.05). Complications were minimal and there were no significant differences between the two groups. This study confirms that pacemakers can be safely implanted in the catheterization laboratory by nonsurgeons with no increase in complications and a significant reduction in hospital costs.
منابع مشابه
THE ROLE OF PACEMAKER CLINIC IN THE FOLLOW-UP OF PATIENTS WITH PERMANENT PACEMAKERS
The Pacemaker Clinic at Shahid Rajai Cardiovascular Research Center first started operating in August 1992. In its first year of operation, 294 permanent pacemaker patients were studied, allowing an appraisal to be carried out of the clinic's effectiveness in diagnosing and treating early complications. In the final analysis, pacemaker complications were observed in 68 (23%) patients, of wh...
متن کاملA cost comparison of balloon angioplasty and stenting versus endarterectomy for the treatment of carotid artery stenosis.
PURPOSE Percutaneous transluminal angioplasty with stenting (PTAS) of the carotid artery has been advocated as an alternative treatment for high-grade stenosis. Rationale for this approach includes less morbidity, shorter recovery, and lower cost when compared with carotid endarterectomy (CEA). METHODS The clinical results and hospital charges of patients who underwent elective treatment for ...
متن کاملHolding Area LINQ Trial (HALT)
BACKGROUND Recent studies have shown that insertable cardiac monitors (ICMs) can be implanted out of the traditional hospital setting and efforts are being made to explore the feasibility of implanting these devices in a specific standardized location other than the operating room or a cardiac catherization/electrophysiology lab. METHODS This was a prospective, non-randomized, single center p...
متن کاملTwo Cases of an Implantation of a Permanent Pacemaker Using a Transaxillary Incision
In surgeries that require the implantation of a pacemaker, the endocardial pacemaker leads are introduced into the cardiac chambers through subclavian or axillary venous catheterization or cephalic vein cutdown. The drawback of this type of surgery is scarring of the pectoral area, which can be a serious cosmetic problem especially for young women. In this study, we report on 2 cases where a pe...
متن کاملErosive Pressure Dermatitis Associated with Cardiac Pacemaker
Erosive dermatitis is a skin reaction associated with implantable cardiac devices (ie, pacemakers and cardioverter defibrillators). We report a 65-year-old man with a history of several cerebrovascular attacks who developed an erythematous crusted erosive patch over the pacemaker site after implantation of two subsequent pacemakers. We suggest that physical irritation may be a trigger factor fo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Pacing and clinical electrophysiology : PACE
دوره 22 12 شماره
صفحات -
تاریخ انتشار 1999