Osseointegration by bone morphogenetic protein-2 and transforming growth factor beta2 coated titanium implants in femora of New Zealand white rabbits

نویسندگان

  • Fritz Thorey
  • Henning Menzel
  • Corinna Lorenz
  • Gerhard Gross
  • Andrea Hoffmann
  • Henning Windhagen
چکیده

BACKGROUND Intramembranous bone formation is essential in uncemented joint replacement to provide a mechanical anchorage of the implant. Since the discovery of bone morphogenic proteins (BMPs) by Urist in 1965, many studies have been conducted to show the influence of growth factors on implant ingrowth. In this study, the influence of bone morphogenetic protein-2 (rhBMP-2) and transforming growth factor β2 (TGF-β2) on implant osseointegration was investigated. MATERIALS AND METHODS Thirty-two titanium cylinders were implanted into the femoral condyles of both hind legs of New Zealand White Rabbits. Four experimental groups were investigated: controls without coating, a macromolecular copolymer + covalently bound BMP-2, adsorbed BMP-2, and absorbed BMP-2+TGF-β2. All samples were analyzed by ex vivo high-resolution micro-computed-tomography after 28 days of healing. Bone volume per total volume (BV/TV) was recorded around each implant. Afterward, all samples were biomechanically tested in a pull-out setup. RESULTS The highest BV/TV ratio was seen in the BMP-2 group, followed by the BMP-2+TGF-β2 group in high-resolution micro-computed-tomography. These groups were significantly different compared to the control group (P < 0.05). Copolymer+BMP-2 showed no significant difference in comparison to controls. In the pull-out setup, all groups showed higher fixation strength compared to the control group; these differences were not significant. CONCLUSIONS No differences between BMP-2 alone and a combination of BMP-2+TGF-β2 could be seen in the present study. However, the results of this study confirm the results of other studies that a coating with growth factors is able to enhance bone implant ingrowth. This may be of importance in defect situations during revision surgery to support the implant ingrowth and implant anchorage.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Surface Modification of Titanium with BMP-2/GDF-5 by a Heparin Linker and Its Efficacy as a Dental Implant

In this study, we prepared human bone morphogenetic protein-2 (hBMP-2)/human growth and differentiation factor-5 (hGDF-5)-coated titanium (Ti) disc and screw types for controlled release of the growth factors (GFs). The two growth factors were coated onto Ti with a smooth surface using their specific interaction with heparin, because they have heparin binding sites in their molecular structures...

متن کامل

Cytokines and growth factors involved in the osseointegration of oral titanium implants positioned using piezoelectric bone surgery versus a drill technique: a pilot study in minipigs.

BACKGROUND Most dental implants are positioned using a drilling surgery technique. However, dentistry recently experienced the implementation of piezoelectric surgery. This technique was introduced to overcome some of the limitations involving rotating instruments in bone surgery. This study used biomolecular and histologic analyses to compare the osseointegration of porous implants positioned ...

متن کامل

Improved osseointegration of dental titanium implants by TiO2 nanotube arrays with recombinant human bone morphogenetic protein-2: a pilot in vivo study

TiO2 nanotube arrays on the surface of dental implants were fabricated by two-step anodic oxidation. Their effects on bone-implant contact were researched by a pilot in vivo study. The implants were classified into four groups. An implant group with TiO2 nanotube arrays and recombinant human bone morphogenetic protein-2 (rhBMP-2) was compared with various surface implants, including machined su...

متن کامل

Assessment of a polyelectrolyte multilayer film coating loaded with BMP-2 on titanium and PEEK implants in the rabbit femoral condyle.

UNLABELLED The aim of this study was to evaluate the osseointegration of titanium implants (Ti-6Al-4V, noted here TA6V) and poly(etheretherketone) PEEK implants induced by a BMP-2-delivering surface coating made of polyelectrolyte multilayer films. The in vitro bioactivity of the polyelectrolyte film-coated implants was assessed using the alkaline phosphatase assay. BMP-2-coated TA6V and PEEK i...

متن کامل

Effect of local TGF-β1 and IGF-1 release on implant fixation: comparison with hydroxyapatite coating

BACKGROUND AND PURPOSE Hydroxyapatite (HA) coating stimulates the osseointegration of cementless orthopedic implants. Recently, locally released osteogenic growth factors have also been shown experimentally to stimulate osseointegration so that bone fills gaps around orthopedic implants. Here, we have compared the effect of local release of TGF-beta1 and IGF-1 with that of hydroxyapatite coatin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 45  شماره 

صفحات  -