Differentiation between different pathological cerebral embolic materials using transcranial Doppler in an in vitro model.

نویسندگان

  • H S Markus
  • M M Brown
چکیده

BACKGROUND AND PURPOSE The detection of circulating particulate cerebral emboli using transcranial Doppler ultrasonography has been recently reported. It has been suggested that this method might allow discrimination between different embolic materials; this would be very useful for selecting specific pharmacological treatment in individual patients. This study was designed to identify those parameters of the Doppler signal that might prove useful in discriminating between different types and sizes of particulate cerebral emboli. METHODS An extracorporeal circuit filled with a saline/Tween solution and driven by a peristaltic pump was used. The tubing was placed in a skull in the position of the middle cerebral artery. Using transcranial Doppler ultrasound, flow was insonated via the transtemporal window. The following embolic materials of measured sizes (range of maximum dimension, 0.5-5.0 mm) were introduced into the circuit: thrombus (n = 20), platelet-rich aggregates (n = 15), atheromatous material (n = 20), and fat (n = 20). The Doppler signal was recorded during the passage of each embolus. Off-line analysis was performed to measure the maximum amplitude and duration of the signal. RESULTS For all embolic materials there was a highly significant relation between embolus size and maximum amplitude of the Doppler signal. The closest correlation was obtained when the logarithm of maximum amplitude was used (for thrombi, r = 0.74; for platelet, r = 0.87; for atheroma, r = 0.46; and for fat, r = 0.68). The slope of the regression line differed for the different embolic materials and was significantly steeper for platelets than for atheroma (p < 0.01). Platelet emboli of maximum dimension < or = 1.5 mm resulted in a significantly lower maximum amplitude than similarly sized atheroma emboli (157 dB versus 206.7 dB, p < 0.01). For larger emboli (> 2 mm) there was little further increase in maximum amplitude with increases in embolus size. For all embolic materials there was a highly significant linear relation between embolus size and duration of the high-amplitude (> 150 dB) signal (for thrombi, r = 0.75; for platelet, r = 0.90; for atheroma, r = 0.77; and for fat, r = 0.86). CONCLUSIONS Platelet emboli result in lower-amplitude signals, and therefore analysis of maximum amplitude may provide information on the type of embolic material. However, it may be difficult to determine whether a given signal is associated with a large platelet embolus or a small atheroma embolus. Duration of the high-amplitude signal will allow accurate estimation of the size of emboli, particularly where the emboli are all of the same material.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effect of velocity on the appearance of embolic signals studied in transcranial Doppler models.

BACKGROUND AND PURPOSE Transcranial Doppler ultrasound can be used to detect circulating cerebral emboli. Recent studies have demonstrated that embolus size is significantly related to both the relative intensity increase and duration of an embolic signal. This may allow information about embolus size to be obtained by analysis of Doppler embolic signals. However, theoretically duration will be...

متن کامل

Turbulence and circulating cerebral emboli detectable at Doppler ultrasonography: a differentiation study in a stenotic middle cerebral artery model.

BACKGROUND AND PURPOSE Blood flow within the middle cerebral artery can be monitored by transcranial Doppler (TCD) ultrasonography. Arterial stenosis can produce turbulent flow, but controversy remains regarding the degree of stenosis needed to cause TCD-detectable turbulence. Furthermore, cerebral emboli and turbulent flow may coexist in the same patient. The current study was designed to stud...

متن کامل

Identification of echocardiographic "smoke" in a bench model with transcranial Doppler ultrasound.

BACKGROUND AND PURPOSE Spontaneous echo contrast in cardiac chamber has been indicated as a source of cerebral embolism. The nature of the echocardiographic smokelike signal is still not fully understood. This study was designed to regenerate spontaneous echo contrast and verify its thromboembolic characters in an in vitro model. METHODS Spontaneous echo contrast was reproduced in an expansio...

متن کامل

Cerebral hemodynamic in patients with major β-Thalassemia using transcranial Doppler sonography

Background: β-thalassemia, a severe form of anemia, is an inherited blood disorder characterized by growth retardation, splenomegaly, and bone abnormalities. Complications related to treatment-induced iron overload also affect the quality of life of patients with major β-thalassemia. Some recent studies indicated cerebral hemodynamic disorders and increased risk of stroke in these patients. The...

متن کامل

High-resolution emboli detection and differentiation by characteristic postembolic spectral patterns.

BACKGROUND AND PURPOSE High-intensity transient signals (HITS) detected by transcranial Doppler ultrasonography correspond to microemboli in intracranial arteries. The purpose of this study was to develop new diagnostic criteria for the differentiation of these microembolic signals from artifact, based on a high-resolution analysis of Doppler power spectra in an in vitro model. METHODS Two hu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Stroke

دوره 24 1  شماره 

صفحات  -

تاریخ انتشار 1993