Direct-current-based image reconstruction versus direct-current included or excluded frequency-domain reconstruction in diffuse optical tomography.
نویسندگان
چکیده
We study the level of image artifacts in optical tomography associated with measurement uncertainty under three reconstruction configurations, namely, by using only direct-current (DC), DC-excluded frequency-domain, and DC-included frequency-domain data. Analytic and synthetic studies demonstrate that, at the same level of measurement uncertainty typical to optical tomography, the ratio of the standard deviation of mu(a) over mu(a) reconstructed by DC only is at least 1.4 times lower than that by frequency-domain methods. The ratio of standard deviations of D (or mu(s)') over D (or mu(s)') reconstructed by DC only are slightly lower than those by frequency-domain methods. Frequency-domain reconstruction including DC generally outperforms that excluding DC, but as the amount of measurements increases, the difference between the two diminishes. Under the condition of a priori structural information, the performances of three reconstruction configurations are seemingly equivalent.
منابع مشابه
The utility of direct-current as compared to frequency domain measurements in spectrally-constrained diffuse optical tomography toward cancer imaging.
This work investigates, by means of analytical and simulation studies, the performance of spectrally-constrained image reconstruction in Continuous-Wave or Direct-Current (DC) and Frequency Domain (FD) near-infrared optical tomography. A recent analytic approach for estimating the accuracy of target recovery and the level of background artifact for optical tomography at single wavelength, based...
متن کاملThe pain and gain of DC-based diffuse optical tomography reconstruction---New insights into an old-like problem
For diffuse optical tomography reconstruction, DC-based method outperforms frequency-domain method in background artifacts, at the known cost of increased coupling between absorption and scattering. The differences of these methods diminish when spatial priors are available. ©2010 Optical Society of America OCIS codes: (170.3880) Medical and biological imaging; (170.3010) Image reconstruction t...
متن کامل“Spectral a priori” to “spatial a posteriori” in continuous-wave image reconstruction in near-infrared optical tomography
This work examines the robustness of spectral prior to continuous-wave based, with respect to frequency domain based, image reconstruction for unique recovering of chromophores and scattering property distributions. An analytical model for parametric uncertainty in recovering optical property is derived, which afterwards is implemented for optimized selection of wavelengths and quality estimati...
متن کاملAn Efficient Method for Model Reduction in Diffuse Optical Tomography
We present an efficient method for the reduction of model equations in the linearized diffuse optical tomography (DOT) problem. We first implement the maximum a posteriori (MAP) estimator and Tikhonov regularization, which are based on applying preconditioners to linear perturbation equations. For model reduction, the precondition is split into two parts: the principal components are consid...
متن کاملImage reconstruction in diffuse optical tomography based on simplified spherical harmonics approximation.
The use of higher order approximations to the Radiative transport equation, through simplified spherical harmonics expansion (SP(N)) in optical tomography are presented. It is shown that, although the anisotropy factor can be modeled in the forward problem, its sensitivity to the measured boundary data is limited to superficial regions and more importantly, due to uniqueness of the inverse prob...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Applied optics
دوره 49 16 شماره
صفحات -
تاریخ انتشار 2010