Efficient storage of microCT data preserving bone morphometry assessment
نویسندگان
چکیده
Preclinical micro-computed tomography (microCT) images are of utility for 3D morphological bone evaluation, which is of great interest in cancer detection and treatment development. This work introduces a compression strategy for microCTs that allocates specific substances in different Volumes of Interest (VoIs). The allocation procedure is conducted by the Hounsfield scale. The VoIs are coded independently and then grouped in a single DICOM-compliant file. The proposed method permits the use of different codecs, identifies and transmit data corresponding to a particular substance in the compressed domain without decoding the volume(s), and allows the computation of the 3D morphometry without needing to store or transmit the whole image. The proposed approach reduces the transmitted data in more than 90% when the 3D morphometry evaluation is performed in high density and low density bone. This work can be easily extended to other imaging modalities and applications that work with the Hounsfield scale.
منابع مشابه
Guidelines for assessment of bone microstructure in rodents using micro-computed tomography.
Use of high-resolution micro-computed tomography (microCT) imaging to assess trabecular and cortical bone morphology has grown immensely. There are several commercially available microCT systems, each with different approaches to image acquisition, evaluation, and reporting of outcomes. This lack of consistency makes it difficult to interpret reported results and to compare findings across diff...
متن کاملThree-Dimensional Quantitative Morphometric Analysis (QMA) for In Situ Joint and Tissue Assessment of Osteoarthritis in a Preclinical Rabbit Disease Model
This work utilises advances in multi-tissue imaging, and incorporates new metrics which define in situ joint changes and individual tissue changes in osteoarthritis (OA). The aims are to (1) demonstrate a protocol for processing intact animal joints for microCT to visualise relevant joint, bone and cartilage structures for understanding OA in a preclinical rabbit model, and (2) introduce a comp...
متن کاملValidation of quantitative magnetic resonance imaging-based apparent bone volume fraction in peri-articular tibial bone of cadaveric knees
BACKGROUND In the knee, high-resolution magnetic resonance (MR) imaging has demonstrated that increased apparent bone volume fraction (trabecular bone volume per total volume; BV/TV) in the peri-articular proximal medial tibia is associated with joint space narrowing and the presence of bone marrow lesions. However, despite evidence of construct validity, MR-based apparent BV/TV has not yet bee...
متن کاملEffect of specimen size on microCT cortical tissue measurements
Aims The increasing interest in cortical bone strenght [1,2] led up to the investigation of the cortical tissue through X-ray microcomputed tomography (microCT). In the past histology has been the gold standard for the morphometric examination of bone specimens but this new method permits the non-destructive analyses of specimens in a faster way preserving the integrity of the samples [3] and t...
متن کاملStereological measures of trabecular bone structure: comparison of 3D micro computed tomography with 2D histological sections in human proximal tibial bone biopsies.
Stereology applied on histological sections is the 'gold standard' for obtaining quantitative information on cancellous bone structure. Recent advances in micro computed tomography (microCT) have made it possible to acquire three-dimensional (3D) data non-destructively. However, before the 3D methods can be used as a substitute for the current 'gold standard' they have to be verified against th...