Newborn Screening for Severe Combined Immunodeficiencies Using Trecs and Krecs: Second Pilot Study in Brazil
نویسندگان
چکیده
OBJECTIVE To validate the quantification of T-cell receptor excision circles (TRECs) and kappa-deleting recombination excision circles (KRECs) by real-time polymerase chain reaction (qRT-PCR) for newborn screening of primary immunodeficiencies with defects in T and/or B cells in Brazil. METHODS Blood samples from newborns and controls were collected on filter paper. DNA was extracted and TRECs, and KRECs were quantified by a duplex real-time PCR. The cutoff values were determined by receiver operating characteristic curve analysis using SPSS software (IBM®, Armonk, NY, USA). RESULTS Around 6,881 samples from newborns were collected and TRECs and KRECs were quantified. The TRECs values ranged between 1 and 1,006 TRECs/µL, with mean and median of 160 and 139 TRECs/µL, respectively. Three samples from patients with severe combined immunodeficiency (SCID) showed TRECs below 4/µL and a patient with DiGeorge syndrome showed undetectable TRECs. KRECs values ranged from 10 to 1,097 KRECs/µL, with mean and median of 130 and 108 KRECs/µL. Four patients with agammaglobulinemia had results below 4 KRECs/µL. The cutoff values were 15 TRECs/µL and 14 KRECs/µL and were established according to the receiver operating characteristic curve analysis, with 100% sensitivity for SCID and agammaglobulinemia detection, respectively. CONCLUSIONS Quantification of TRECs and KRECs was able to diagnose children with T- and/or B-cell lymphopenia in our study, which validated the technique in Brazil and enabled us to implement the newborn screening program for SCID and agammaglobulinemia.
منابع مشابه
T-cell Receptor and K-deleting Recombination Excision Circles in Newborn Screening of T- and B-cell Defects: Review of the Literature and Future Challenges
Since its introduction as a public health programme in the United States in the early 1960s, newborn blood screening (NBS) has evolved from the detection of phenylalanine levels on filter paper to the application of DNA-based technologies to identify T-cell lymphopenia in infants with severe combined immunodeficiency. This latter use of NBS has required the development of an assay for T-cell ly...
متن کاملNeonatal screening for severe combined immunodeficiency in Brazil.
OBJECTIVE To apply, in Brazil, the T-cell receptor excision circles (TRECs) quantification technique using real-time polymerase chain reaction in newborn screening for severe combined immunodeficiency and assess the feasibility of implementing it on a large scale in Brazil. METHODS 8715 newborn blood samples were collected on filter paper and, after DNA elution, TRECs were quantified by real-...
متن کاملA Call to Include Severe Combined Immunodeficiency in Newborn Screening Program
UNLABELLED Quantification of the T cell receptor excision circles (TRECs) has recently emerged as a useful non-invasive clinical and research tool to investigate thymic activity. It allows the identification of T cell production by the thymus. Quantification of TREC copies has recently been implemented as the preferred test to screen neonates with severe combined immunodeficiency (SCID) or sign...
متن کاملPID Comes Full Circle: Applications of V(D)J Recombination Excision Circles in Research, Diagnostics and Newborn Screening of Primary Immunodeficiency Disorders
The vast majority of patients suffering from a primary immunodeficiency (PID) have defects in their T- and/or B-cell compartments. Despite advances in molecular diagnostics, in many patients no underlying genetic defect has been identified. B- and T-lymphocytes are unique in their ability to create a receptor by genomic rearrangement of their antigen receptor genes via V(D)J recombination. Duri...
متن کاملNeonatal screening for severe primary immunodeficiency diseases using high-throughput triplex real-time PCR.
Severe combined immunodeficiency (SCID) and X-linked agammaglobulinemia (XLA) are inborn errors of immune function that require prompt diagnosis and treatment to prevent life-threatening infections. The lack of functional T or B lymphocytes in these diseases serves as a diagnostic criterion and can be applied to neonatal screening. A robust triplex PCR method for quantitation of T-cell receptor...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 35 شماره
صفحات -
تاریخ انتشار 2017