MRI of Perfusion-Diffusion Mismatch in Non-Human Primate (Baboon) Stroke: A Preliminary Report
نویسندگان
چکیده
The goal of this study was to develop a clinically relevant non-human primate (baboon) stroke model and multi-parametric MRI protocols on a clinical scanner with long-term goals to better model human stroke and facilitate clinical translations of novel therapeutic strategies. Baboons were chosen because of their relatively large brain volume and that they are evolutionarily close to humans. Middle cerebral artery occlusion (MCAO) was induced using a minimally invasive endovascular approach to guide an inflatable balloon catheter into the MCA and followed by permanently or transiently inflate the balloon. Using multimodal MRI, including perfusion and diffusion imaging, the spatiotemporal dynamic evolution of the ischemic lesions in permanent and transient occlusion experiments in baboons were investigated. Perfusion-diffusion mismatch, which approximates the ischemic penumbra, was detected. In the permanent MCAO group (n = 2), the mean infarct volume was 29 ml (17% of total brain volume) whereas in the transient MCAO group (n = 2, 60 or 90 min of occlusion), the mean infarct volume was 15 ml (9% of total brain volume). Substantial perfusion-diffusion mismatch tissue (~50%) was salvaged by reperfusion compared to permanent MCAO. This baboon stroke model has the potential to become a translational platform to better design clinical studies, guide clinical diagnosis and improve treatment time windows in patients.
منابع مشابه
Diffusion tensor and perfusion MRI of non-human primates.
This paper reviews recent non-human primate (NHP) neuroimaging literature using MRI in macaque, baboon and chimpanzee. It describes general challenges and limitations for NHP MRI studies, and reviews recent applications of anatomical, diffusion tensor, cerebral blood flow MRI. Applications to NHP stroke is discussed in some detail.
متن کاملMagnetic resonance imaging of perfusion-diffusion mismatch in rodent and non-human primate stroke models.
Stroke is a leading cause of death and long-term disability. Non-invasive magnetic resonance imaging (MRI) has been widely used for the early detection of ischemic stroke and the longitudinal monitoring of novel treatment strategies. Recent advances in MRI techniques have enabled improved sensitivity and specificity to detecting ischemic brain injury and monitoring functional recovery. This rev...
متن کاملDiffusional Kurtosis Imaging in Acute Human Stroke
The management of acute human stroke is a high-priority medical emergency. Thrombolytic therapy is now part of the standard of care in most major medical centers, and the selection of patients for these treatments depends on several clinical factors as well as brain imaging findings. Diffusion MRI combined with perfusion imaging are accepted imaging protocols used to characterize ischemic strok...
متن کاملCT-NIHSS mismatch does not correlate with MRI diffusion-perfusion mismatch.
BACKGROUND AND PURPOSE MRI diffusion-perfusion mismatch may identify patients for thrombolysis beyond 3 hours. However, MRI has limited availability in many hospitals. We investigated whether mismatch between the Alberta Stroke Program Early CT Score (ASPECTS) and the NIH Stroke Scale (NIHSS) correlates with MRI diffusion-perfusion mismatch. METHODS We retrospectively analyzed a cohort of con...
متن کاملPerfusion-diffusion Mismatch Predicts Early Neurological Deterioration in Anterior Circulation Infarction without Thrombolysis
Perfusion-diffusion mismatch in magnetic resonance imaging (MRI) represents the non-core hypoperfused area in acute ischemic stroke. The mismatch has been used to predict clinical response after thrombolysis in acute ischemic stroke, but its role for predicting early neurological deterioration (END) in acute ischemic stroke without thrombolysis has not been clarified yet. In this study, we pros...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 5 شماره
صفحات -
تاریخ انتشار 2011