Evaluation of the technical performance of novel holotranscobalamin (holoTC) assays in a multicenter European demonstration project.
نویسندگان
چکیده
A commercially available holotranscobalamin (holo-TC) radioimmunoassay (RIA) (Axis-Shield, Dundee, Scotland) was evaluated in four laboratories and compared with a holoTC ELISA run in one laboratory. The performance of the holoTC RIA assay was comparable in three of the four participating laboratories. The results from these three laboratories, involving at least 20 initial runs of "low", "medium" and "high" serum-based controls (mean holoTC concentrations 34, 60 and 110 pmol/L, respectively) yielded an intra-laboratory imprecision of 6-10%. No systematic inter-laboratory deviations were observed on runs involving 72 patient samples (holoTC concentration range 10-160 pmol/L). A fourth laboratory demonstrated higher assay imprecision for control samples and systematic deviation of results for the patient samples. Measurement of holoTC by ELISA showed an imprecision of 4-5%, and slightly higher mean values for the controls (mean holoTC concentrations 40, 70 and 114 pmol/L, respectively). Comparable results were obtained for the patient samples. The long-term intra-laboratory imprecision was 12% for the holoTC RIA and 6% for the ELISA. In conclusion, it would be prudent to check the calibration and precision prior to starting to use these holoTC assays in research or clinical practice. The results obtained using the holoTC RIA were similar to those obtained using the holoTC ELISA assay.
منابع مشابه
Performance characteristics of the ARCHITECT Active-B12 (Holotranscobalamin) assay.
BACKGROUND Vitamin B12 (cobalamin) is a necessary cofactor in methionine and succinyl-CoA metabolism. Studies estimate the deficiency prevalence as high as 30% in the elderly population. Ten to thirty percent of circulating cobalamin is bound to transcobalamin (holotranscobalamin, holoTC) which can readily enter cells and is therefore considered the bioactive form. The objective of our study wa...
متن کاملHolotranscobalamin and total transcobalamin in human plasma: determination, determinants, and reference values in healthy adults.
BACKGROUND We developed microbiological assays (MBAs) to identify determinants and to establish reference values for cobalamin bound to transcobalamin [holotranscobalamin (holoTC)] and total TC in plasma. METHODS We captured holoTC with magnetic beads with TC antibodies and used a conventional MBA for cobalamin measurements. Total TC was determined as holoTC after TC was saturated with cyanoc...
متن کاملVitamin B12 absorption judged by measurement of holotranscobalamin, active vitamin B12: evaluation of a commercially available EIA kit.
BACKGROUND Active vitamin B12 absorption is followed by an increase in holotranscobalamin (holoTC) upon loading with a high physiological dose of the vitamin (the CobaSorb test). This study evaluates the use of a newly launched EIA kit for measurement of holoTC (active B12) in relation to the CobaSorb test. METHODS Intra-assay imprecision and linearity of the EIA kit was examined, employing s...
متن کاملAnaemia and Haemoglobinuria Holotranscobalamin – An Early Marker for Laboratory Diagnosis of Vitamin B12 Deficiency
Vitamin B12 deficiency is widespread. Among the population groups at risk are older people, vegetarians, pregnant women and patients with renal or intestinal diseases. The neurological symptoms of vitamin B12 deficiency are unspecific and can be irreversible. Early detection is therefore important. This article reviews the diagnostic performance of the different laboratory markers for vitamin B...
متن کاملHolotranscobalamin (HoloTC, Active-B12) and Herbert’s model for the development of vitamin B12 deficiency: a review and alternative hypothesis
The concentration of total vitamin B12 in serum is not a sufficiently sensitive or specific indicator for the reliable diagnosis of vitamin B12 deficiency. Victor Herbert proposed a model for the staged development of vitamin B12 deficiency, in which holotranscobalamin (HoloTC) is the first indicator of deficiency. Based on this model, a commercial immunoassay has been controversially promoted ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical chemistry and laboratory medicine
دوره 43 10 شماره
صفحات -
تاریخ انتشار 2005