Reproducibility of glucose measurements using the glucose sensor.

نویسندگان

  • Muriel Metzger
  • Gil Leibowitz
  • Julio Wainstein
  • Benjamin Glaser
  • Itamar Raz
چکیده

OBJECTIVE Recent studies have confirmed that improved glycemic control decreases the risk of diabetic complications in type 1 and type 2 diabetic patients. The Minimed glucose sensor allows continuous 72-h glucose monitoring and represents a potentially important tool to improve diabetes management. Its use is currently limited to the health care team. Our aim was to evaluate the reproducibility of data provided by the device by comparing data provided by two sensors worn simultaneously by the same subject. RESEARCH DESIGN AND METHODS A total of 11 subjects (6 type 1 and 3 type 2 diabetic patients and 2 healthy subjects) agreed to wear two sensors and perform at least four daily finger-stick glucose determinations during 72 h. The simultaneous glucose values provided by the sensors were compared. To determine the clinical implications of the glucose data, each day was divided into eight periods, and for each period the glucose range was rated as satisfactory, too high, or too low by a blinded clinician experienced in interpreting glucose sensor data in the clinical setting. The evaluation of glycemic levels based on the recordings of the two sensors were compared for each paired time interval. RESULTS We discarded 18% of the sensor data for technical reasons. Examined as a group, the remaining 3,370 paired data points in all 11 patients were highly correlated (r = 0.84). However, when individual pairs were evaluated, large differences in the glucose values were apparent, with differences of >10% in 70% of the measurements and >50% in 7% of the measurements. Moreover, clinical evaluation of the glucose range provided simultaneously by two sensors was concordant for only 65% of the evaluation periods. CONCLUSION In a real-life setting, the accuracy of data provided by the Minimed glucose sensor may be less than expected. To avoid therapeutic errors, sensor findings should be confirmed by independent means before clinical decisions are made.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Comparative Study of Blood Glucose Measurements Using Glucometer Readings and the Standard Method in the Diagnosis of Neonatal Hypoglycemia

Background: Hypoglycemia is one of the most common neonatal disorders, associated with severe complications. There has been a great deal of controversy regarding the definition and screening of hypoglycemia. Therefore, in this study, we aimed to determine a cut-off value for blood glucose level in glucometer readings. Methods: This cross-sectional study was conducted on 238 newborns at risk of ...

متن کامل

A fiber optic sensor for measuring glucose in aqueous solutions

In this paper, the set-up of a multi-mode fiber optic sensor for measuring glucose in aqueous solutions is investigated and evaluated. The basis of this sensor is based on the Fresnel Reflection. In this setup, a helium-neon laser is used as a light source, a fiber optic probe, photocell as detector and a digital multimeter. The statistical analysis of the recorded data shows a highly linear be...

متن کامل

Determining Blood Glucose Concentration using Near Infrared Spectroscopy: Early Findings

Introduction: Diabetes mellitus is one of the diseases that have grown dramatically in today's societies. People with diabetes should continuously measure their blood glucose level. Continuous blood glucose measurement by commonly used methods is painful and difficult. On the other hand, mobile phone can be a useful tool for accessing physicians and telemedicine services more easily. The aim of...

متن کامل

Determining Blood Glucose Concentration using Near Infrared Spectroscopy: Early Findings

Introduction: Diabetes mellitus is one of the diseases that have grown dramatically in today's societies. People with diabetes should continuously measure their blood glucose level. Continuous blood glucose measurement by commonly used methods is painful and difficult. On the other hand, mobile phone can be a useful tool for accessing physicians and telemedicine services more easily. The aim of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Diabetes care

دوره 25 7  شماره 

صفحات  -

تاریخ انتشار 2002