CT colonography: inverse-consistent symmetric registration of prone and supine inner colon surfaces

نویسندگان

  • Holger Roth
  • Jamie McClelland
  • Marc Modat
  • Thomas Hampshire
  • Darren Boone
  • Emma Helbren
  • Andrew Plumb
  • Mingxing Hu
  • Sébastien Ourselin
  • Steve Halligan
  • David J. Hawkes
چکیده

CT colonography interpretation is difficult and time-consuming because fecal residue or fluid can mimic or obscure polyps, leading to diagnostic errors. To compensate for this, it is normal practice to obtain CT data with the patient in prone and supine positions. Repositioning redistributes fecal residue and colonic gas; fecal residue tends to move, while fixed mural pathology does not. The cornerstone of competent interpretation is the matching of corresponding endoluminal locations between prone and supine acquisitions. Robust and accurate automated registration between acquisitions should lead to faster and more accurate detection of colorectal cancer and polyps. Any directional bias when registering the colonic surfaces could lead to incorrect anatomical correspondence resulting in reader error. We aim to reduce directional bias and so increase robustness by adapting a cylindrical registration algorithm to penalize inverse-consistency error, using a symmetric optimization. Using 17 validation cases, the mean inverse-consistency error was reduced significantly by 86%, from 3.3 mm to 0.45 mm. Furthermore, we show improved alignment of the prone and supine colonic surfaces, evidenced by a reduction in the mean-of-squared-differences by 43% overall. Mean registration error, measured at a sparse set of manually selected reference points, remained at the same level as the non-symmetric method (no significant differences). Our results suggest that the inverse-consistent symmetric algorithm performs more robustly than non-symmetric implementation of B-spline registration.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

WE-E-213CD-03: Inverse-Consistent Symmetric Registration of Inner Colon Surfaces Derived from Prone and Supine CT Colonography.

PURPOSE Robust registration of prone and supine colonie surfaces acquired during CT colonography may lead to faster and more accurate detection of colorectal cancer and polyps. Any directional bias when registering one surface to the other could precipitate incorrect anatomical correspondence and engender reader error. Despite this, non-rigid registration methods are often implemented asymmetri...

متن کامل

Establishing Spatial Correspondence between the Inner Colon Surfaces from Prone and Supine CT Colonography

Colonography is an important screening tool for colorectal lesions. This paper presents a method for establishing spatial correspondence between prone and supine inner colon surfaces reconstructed from CT colonography. The method is able to account for the large deformations and torsions of the colon occurring through movement between the two positions. Therefore, we parameterised the two surfa...

متن کامل

Intra-Patient Supine-Prone Colon Registration in CT Colonography Using Shape Spectrum

CT colonography (CTC) is a minimally invasive screening technique for colorectal polyps and colon cancer. Since electronic colon cleansing (ECC) cannot completely remove the presence of pseudo-polyps, most CTC protocols acquire both prone and supine images to improve the visualization of the lumen wall and to reduce false positives. Comparisons between the prone and supine images can be facilit...

متن کامل

Deformable Registration of Supine and Prone Colons for CT Colonography

CT colonography (CTC) is a minimally invasive screening technique for colorectal polyps and colon cancer. Most CTC protocols acquire both prone and supine images to improve the visualization of the lumen wall, reduce false positives, and improve sensitivity. Comparisons between the prone and supine images can be facilitated by computerized registration between the scans. In this paper, an algor...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013