Effects of ampholyte concentration on protein behavior in on-chip isoelectric focusing.

نویسندگان

  • Jaesool Shim
  • Prashanta Dutta
  • Cornelius F Ivory
چکیده

The effects of mobility corrections on carrier ampholytes are studied at various ampholyte concentrations to understand protein behavior during IEF. IEF simulations are conducted in the presence of 25 biprotic carrier ampholytes within a pH range of 6-9 after applying the Onsager-Debye-Hückel correction to the carrier ampholytes. Two model proteins with ten charge states but without ionic strength corrections are allowed to focus under an electric field of 300 V/cm in a 1 cm long channel. The IEF simulation results show that higher ionic strengths (50 - 100 mM) cause significant changes in the transient movement as well as the final focused profiles of both ampholytes and proteins. The time required for a single, well-defined peak to form increases with ionic strength when Onsager corrections are applied to the carrier ampholytes. For a particular ampholyte concentration, the space-averaged conductivity does not change during the final focusing stage, but the magnitude of space averaged conductivity is different for different ampholyte concentration. The simulation results also reveal that at steady-state ionic strength profiles remain flat throughout the channel except at the locations of proteins where a significant change in ampholyte concentration is obtained.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of ampholyte dissociation constants on protein separation in on-chip isoelectric focusing.

Numerical simulations are presented for ampholyte-based isoelectric focusing in 2D microgeometries. In this study, model proteins are focused in the presence of 25 biprotic ampholytes under an applied electric field. Each protein is considered as a simple polypeptide having ten charge states, while the biprotic ampholytes are selected to generate a shallow pH range of 6 to 9. Straight and contr...

متن کامل

Microfluidic 2-D PAGE using multifunctional in situ polyacrylamide gels and discontinuous buffers.

A two-dimensional microfluidic system is presented for intact protein separations combining isoelectric focusing (IEF) and sodium dodecyl sulfate (SDS) polyacrylamide gel electrophoresis (PAGE) employing in situ photopolymerized polyacrylamide (PAAm) gels. The PAAm gels are used for multiple functions. In addition to serving as a highly-resolving separation medium for gel electrophoresis, discr...

متن کامل

On-chip coupling of isoelectric focusing and free solution electrophoresis for multidimensional separations.

We have developed an acrylic microfluidic device that sequentially couples liquid-phase isoelectric focusing (IEF) and free solution capillary electrophoresis (CE). Rapid separation (<1 min) and preconcentration (73x) of species were achieved in the initial IEF dimension. Using full-field fluorescence imaging, we observed nondispersive mobilization velocities on the order of 20 microm/s during ...

متن کامل

THE INFLUENCE OF pH UPON THE CONCENTRATION POTENTIALS ACROSS THE SKIN OF THE FROG

The production of concentration P.D.'s across the skin of the frog is very intimately related to the pH of the applied solutions. On the alkaline side of an isoelectric point the dilute solution is electropositive; on the acid side this solution becomes electronegative. When the pH is suddenly lowered from a value more alkaline than this isoelectric point to one considerably more acid the chang...

متن کامل

Isoelectric focusing of proteins in rewetted ultrathin polyacrylamide gel layers.

Ultrathin layers of polyacrylamide gel bound to glass can be washed, air-dried, and stored for at least 1 year before rewetting in ampholyte solutions for isoelectric focusing. Short-term drying affects neither fluorescent banding of the ampholytes (not evident in conventional gels) nor resolution of complex protein mixtures while prolonged storage seems to have no deleterious effects. Layers a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Electrophoresis

دوره 29 5  شماره 

صفحات  -

تاریخ انتشار 2008