Anaesthesia at remote location: use of modified Bain circuit (Mapleson D) at Kunri Christian Hospital (KCH).

نویسندگان

  • Ehtesham Izhar Khan
  • Hameed Ullah
  • Rehana Kamal
چکیده

OBJECTIVE To develop a safe general anaesthesia technique for remote areas with lack of facilities. METHODS Four types of anaesthesia techniques using TIVA and modified Bain circuit were planned. Monitoring facility was limited to manual sphygmomanometer, palpation of radial pulse and monitoring of colour of skin and blood. Depth of anaesthesia was assessed using EVANs, RPST scoring system. Patients were asked in recovery room for awareness. RESULTS Surgeries done were cesarean sections, laparotomies, gynaecological, urological, hernia and burn contractures. Six patients had RPST score of 5 or more and three patients in recovery room complained of awareness. Cost per Anaesthesia was Rs225. CONCLUSION TIVA with modified Bain circuit provided effective anaesthesia in remote area at low cost.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Isoflurane leakage from non-rebreathing rodent anaesthesia circuits: comparison of emissions from conventional and modified ports.

Chronic exposure to low levels of fluorocarbon-based waste anaesthetic gas (WAG) has been linked to a multitude of human health problems. We have shown that isoflurane exhaust from passive gas-scavenging canisters is often quite high when using conventional rodent anaesthesia protocols and equipment. Another likely source of WAG build-up in rodent procedure rooms is leakage at the interface bet...

متن کامل

Drawover anaesthesia and preoxygenation.

We have studied the efficacy of preoxygenation using the Triservice Anaesthetic Apparatus (TSA) in healthy patients and found it to be unsatisfactory. An alternative technique suitable for field use was explored. The Mapleson D system (Bain) was found to be suitable for preoxygenation with a fresh gas flow of only 4 litre of oxygen per minute. In a randomized study using only 4 litre of oxygen ...

متن کامل

Will we ever have a universal anaesthetic breathing system.

In this issue of the JOURNAL, Humphrey and his colleagues describe a version of the A.D.E. anaesthetic breathing system 1'2 which they feel is optimal for all patients. Humphrey et al . have shown that the "A.D.E. low-flow universal" system functions as a modified D (Mapleson's classification 3) or Bain circuit for controlled ventilation and, with the switch of a single lever, as a modified Map...

متن کامل

Continuous subcutaneous injection of ketamine for cancer pain.

To the Editor: Bain circuits which we presently use are designed with a coloured delivery tube so that kinks or obstructions to the tube will be easily Seen. We received a new Bain circuit which appeared intact, but when it was placed on the anaesthetic machine, it provided no gas flow at the patient end. On examining the circuit, the delivery tube was obstructed and kinked at the proximal end....

متن کامل

A simple and inexpensive device for administration of continuous positive airway pressure breathing.

A simple system for administration of continuous positive airway pressure breathing uses a corrugated hose in the modified Mapleson D system for anaesthesia. The only mechanical component of the system is a spring-loaded valve for positive end expiratory pressure.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • JPMA. The Journal of the Pakistan Medical Association

دوره 59 7  شماره 

صفحات  -

تاریخ انتشار 2009