The analysis of efficacy for AutoPulse™ system in flying helicopter.
نویسندگان
چکیده
AIM OF THE STUDY The helicopter emergency medical service (HEMS) was introduced in Japan in 2001, and some cardiopulmonary arrest (CPA) patients are transported using this service. However, it is difficult to maintain continuous and effective manual cardiopulmonary resuscitation (CPR) in flying helicopters. To overcome this problem, the AutoPulse™ system, automated mechanical CPR devices, was induced. We conducted a retrospective study to clarify the efficacy of AutoPulse™ on CPA patients in flying helicopters. METHODS In total, 92 CPA patients were enrolled in this study. Of these, 43 CPA patients received manual CPR (between April 2004 and June 2008), and 49 patients received AutoPulse™ CPR (between July 2008 and March 2011). We compared the manual CPR group with the AutoPulse™ group using logistic regression analysis and examined the efficacy of AutoPulse™ in flying helicopters. RESULTS Rates for return of spontaneous circulation (ROSC) and survival to hospital discharge were increased in the AutoPulse™ group compared to the manual CPR group (ROSC, 30.6% [15 patients] vs. 7.0% [3 patients]; survival to hospital discharge, 6.1% [3 patients] vs. 2.3% [1 patient]). In multivariate analysis, the factors associated with ROSC were the use of AutoPulse™ (odds ratio [OR], 7.22; P=0.005) and patients aged ≤65 years (OR, 0.31; P=0.042). CONCLUSION The present study demonstrates that the use of AutoPulse™ in flying helicopters was significantly effective for the ROSC in CPA patients. The use of automated chest compression devices such as AutoPulse™ might be recommended at least for CPA patients transported by helicopters.
منابع مشابه
Efficacy of virtual reality exposure therapy in reducing anxiety symptoms in Iranian individuals with flying phobia
Objective: Virtual reality exposure has recently emerged as an innovative tool for exposure therapy in the treatment of fear of flying. Fear of flying, a key component of which is anxiety, often remains uncured if no intervention procedures are employed. Not to point to the fact that about 10 to 25 percent of all the individuals experience anxiety and that causes the individual entirely to avo...
متن کاملHelicopter Blade Stability Analysis Using Aeroelastic Frequency Response Functions
In the present paper, the aeroelastic stability of helicopter rotor blade is determined using Aeroelastic Frequency Response Function. The conventional methods of aeroelastic stability usually use an iterative procedure while the present method does not require such approach. Aeroelastic Frequency Response Functions are obtained by inverting dynamic stiffness matrix of the aeroelastic system. S...
متن کاملIntelligent Auto pilot Design for a Nonlinear Model of an Autonomous Helicopter by Adaptive Emotional Approach
There is a growing interest in the modeling and control of model helicopters using nonlinear dynamic models and nonlinear control. Application of a new intelligent control approach called Brain Emotional Learning Based Intelligent Controller (BELBIC) to design autopilot for an autonomous helicopter is addressed in this paper. This controller is applied to a nonlinear model of a helicopter. This...
متن کاملCoupled Flap-Lag-Torsional Vibration Analysis of Pre-twisted Non-uniform Helicopter Blades
An approximate numerical mthod is presented for analysis and determination of modal characteristics in straight, pretwisted non-unifom helicopter blades. The analysis considers the coupled flapwise bending (out of plane), chordwise bending (in plane), and torsion vibration of both rotating and non-rotating blades. The proposed method is based on the integral expansion of Green functions (struct...
متن کاملHarmonic Reduction Technique Using Flying Capacitor Based Z Source Inverter for a DVR
The Dynamic Voltage Restorer (DVR) is a commercially available, popular device to eliminate voltage sags and swells in the distribution lines. Its basic function is to inject the voltage difference (difference between the pre-sag and sag voltage) to the power line and maintains the pre-sag voltage condition in the load side. The efficiency of the DVR depends on the performance of the efficiency...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Resuscitation
دوره 84 8 شماره
صفحات -