Three-Dimensional Analysis of the Characteristics of the Femoral Canal Isthmus: An Anatomical Study

نویسندگان

  • Xiu-yun Su
  • Jing-xin Zhao
  • Zhe Zhao
  • Li-cheng Zhang
  • Chen Li
  • Jian-tao Li
  • Jian-feng Zhou
  • Li-hai Zhang
  • Pei-fu Tang
چکیده

PURPOSE To establish a new approach for measuring and locating the femoral intramedullary canal isthmus in 3-dimensional (3D) space. METHODS Based on the computed tomography data from 204 Chinese patients, 3D models of the whole femur and the corresponding femoral isthmus tube were reconstructed using Mimics software (Materialise, Haasrode, Belgium). The anatomical parameters of the femur and the isthmus, including the femur length and radius, and the isthmus diameter and height, were measured accordingly. RESULTS The mean ratio of the isthmus height versus the femoral height was 55 ± 4.8%. The mean diameter of the isthmus was 10.49 ± 1.52 mm. The femoral length, the isthmus diameter, and the isthmus tube length were significantly larger in the male group. Significant correlations were observed between the femoral length and the isthmus diameter (r = 0.24, p < 0.01) and between the femoral length and the isthmus height (r = 0.6, p < 0.01). Stepwise linear regression analyses demonstrated that the femoral length and radius were the most important factors influencing the location and dimension of the femoral canal isthmus. CONCLUSION The current study developed a new approach for measuring the femoral canal and for optimization of customer-specific femoral implants.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Incidence, location, and type of isthmus in mandibular second molars among individuals of an Iranian population

BACKGROUND AND AIM: Isthmuses are narrow and strip shaped connections between two canals containing pulpal tissue that may encompass bacteria as well. They are hardly accessible for cleaning; therefore, success and failure of root canal treatments could be affected by their presence. The present study was carried out aiming to evaluate the incidence, location, and type of isthmus in mandibular ...

متن کامل

Immediate effects of femoral external rotational and abductoral taping on ground reaction force characteristics during running

Introduction and aim: Taping is a common method used by athletes to improve muscular function. The aim was to assess the immediate effect of femoral external rotational and abductoral taping on three-dimensional ground reaction force characteristics, their time to peak, impulse, displacement of center of pressure, vertical loading rate, and free moment during stance phase of running. Method: 24...

متن کامل

Morphological Study of the Newly Designed Cementless Femoral Stem

A morphology study was essential to the development of the cementless femoral stem because accurate dimensions for both the periosteal and endosteal canal ensure primary fixation stability for the stem, bone interface, and prevent stress shielding at the calcar region. This paper focused on a three-dimensional femoral model for Asian patients that applied preoperative planning and femoral stem ...

متن کامل

Three-Dimensional Analysis of the Curvature of the Femoral Canal in 426 Chinese Femurs

PURPOSE The human femur has long been considered to have an anatomical anterior curvature in the sagittal plane. We established a new method to evaluate the femoral curvature in three-dimensional (3D) space and reveal its influencing factors in Chinese population. METHODS 3D models of 426 femurs and the medullary canal were constructed using Mimics software. We standardized the positions of a...

متن کامل

Three Dimensional Morphometry of Proximal Femur to Design Best-Fit Femoral Stem for Indonesian Population Morfometría Tridimensional del Fémur Proximal para Diseñar Prótesis a Medida en la Población de Indonesa

To design custom-made prosthesis in a certain population, the morphometry needs to be measured. The results of this study were expected to provide basic data to design the ideal size of the total hip arthoplasty prosthesis for Indonesian population. This was an anthropometric study conducted on sex matched 100 healthy Indonesian mongoloid race subjects based on Computer Tomographic (CT) imaging...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 2015  شماره 

صفحات  -

تاریخ انتشار 2015