An accurate method of radiological assessment of acetabular volume and orientation in computed tomography spatial reconstruction

نویسندگان

  • Marek Jóźwiak
  • Michał Rychlik
  • Bartosz Musielak
  • Brian Po-Jung Chen
  • Maciej Idzior
  • Andrzej Grzegorzewski
چکیده

BACKGROUND Two-dimensional (2D) measurements of acetabular morphology and orientation are well known; there is less information on these acetabular characteristics in three dimensions. One important reason is the lack of standardized reference planes for the pelvis, especially in relation to the spinopelvic unit; another is that no method precisely assesses the acetabulum in three-dimensional (3D) orientation based on its axis rather than on the directions of the edges of the acetabular rim. We present an objective, highly reliable and accurate, axis-based approach to acetabular anthropometry in the measurement of acetabular volume and spatial orientation in both normal and pathologic hips. This was done using reference planes based on the sacral base (SB) and true acetabular axis in 3D computed tomography (CT) pelvic reconstruction. METHODS Radiological examinations of 30 physiologic pelves (60 acetabula) were included in the study. Reliability and accuracy of the method were verified by comparing acetabular angles in 2D pelvic scans with 3D reconstructions. We also applied the method to two pathologic acetabula. RESULTS Comparison of axis position in the horizontal plane revealed significant positive correlations between 2D angle measurements (acetabular anteversion angle [AAA] and anterior acetabular index [AAI]) and 3D measurement of anteversion angle (p < 0.001 and p = 0.012, respectively). In the frontal plane, there was no difference between abduction angle, measured on topogram, and inclination angle, obtained from a 3D model (p = 0.517). In the sagittal plane, there was a significant negative correlation between AAA and acetabular tilt (p < 0.001). Inter- and intra-observer reproducibility was excellent for determination of the sacral-base plane and assessment of volume, with Fleiss κ coefficients of 0.850 and 0.783, respectively, and intraclass correlation coefficients of 0.900 and 0.950, respectively. Inter-observer reproducibility for evaluation of acetabular axis ranged from 0.783 to 0.883, and intra-rater reliability ranged from 0.850 to 0.900 for all 3D angles. CONCLUSIONS Our method is a new, reliable diagnostic tool for assessing the acetabula in both normal and pathologic hip joints. The sacral-base plane can be used as a stable reference that takes the relationship of the acetabulum to the spinopelvic unit into consideration.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dose Assessment in Computed Tomography Examination and Establishment of Local Diagnostic Reference Levels in Mazandaran, Iran

Background: Medical X-rays are the largest man-made source of public exposure to ionizing radiation. While the benefits of Computed Tomography (CT) are well known in accurate diagnosis, those benefits are not risk-free. CT is a device with higher patient dose in comparison with other conventional radiation procedures. Objective: This study is aimed at evaluating radiation dose to patients from ...

متن کامل

Artifact reduction techniques in Cone Beam Computed Tomography (CBCT) imaging modality

Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalitie...

متن کامل

Usability assessment of cone beam computed tomography with a full-fan mode bowtie filter compared to that with a half-fan mode bowtie filter

Background: In intensity modulated radiation therapy, cone beam computed tomography (CT) has been used to evaluate patients prior to treatment. This study conducted a comparative evaluation of the image reconstruction ability of the clinically used half-fan bowtie filter and the full-fan bowtie filter. Materals and Methods: A CT simulation marker was inserted inside a human phantom, and the pel...

متن کامل

Research Paper: Anthropometric Study of Hip Joint in Tehran Population Using Computed Tomography Scan

Introduction: Anthropometric studies provide valuable information in different populations. This study was conducted to evaluate the anatomical variations of the normal hip joint among Tehran population, Iran, in comparison with other populations. Methods: This study was carried out on hip joint of 260 patients in all ages and both genders referred to the Department of Radiology at Ebn-e Sina ...

متن کامل

Validation of a computer navigation system and a CT method for determination of the orientation of implanted acetabular cup in total hip arthroplasty: a cadaver study.

BACKGROUND Successful hip reconstruction to restore the normal hip biomechanics requires precise placement of implants. Computer assisted navigation in total hip arthroplasty has been proposed to have the potential to help achieve a high accuracy in implant placement. The goal of the study was to evaluate the accuracy of an imageless computer navigation system on cadavers and to validate a non-...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2015