Effect of light scattering from source optics in goniometric diffuse reflectance measurements

نویسندگان

  • Silja Holopainen
  • Farshid Manoocheri
  • Saulius Nevas
  • Erkki Ikonen
چکیده

The significance of light scattering around the main beam in a gonioreflectometer based measurement of spectral diffuse reflectance is discussed. This kind of scatter is always present in goniometric measurement systems that use a shaped measurement beam. Furthermore, errors due to this effect are a potential cause of discrepancies between goniometer and integrating-sphere based measurement methods. Procedures used to determine such errors and the required corrections are presented. At the Helsinki University of Technology, the determined wavelength-dependent correction in the worst case was as high as −1.6% and could be reduced to −0.2% with improvements in the optical setup of the gonioreflectometer. The measurement results for our diffuse reflectance reference materials with the appropriate corrections in each case are in good agreement, which gives a new view on some measurements reported earlier.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

White light oblique incidence reflectometer formeasuring absorption and reduced scatteringspectra of tissue-like turbid media.

We designed a quick and inexpensive system for spectral measurements of optical properties including absorption coefficient and reduced scattering coefficient. The system was based on oblique incidence reflectometry.[1] A broad band light source was coupled into an optic fiber to deliver light obliquely to turbid media. Nine detection optic fibers were used to collect the diffuse reflectance as...

متن کامل

Spatially resolved absolute diffuse reflectance measurements for noninvasive determination of the optical scattering and absorption coefficients of biological tissue.

The absorption and transport scattering coefficients of biological tissues determine the radial dependence of the diffuse reflectance that is due to a point source. A system is described for making remote measurements of spatially resolved absolute diffuse reflectance and hence noninvasive, noncontact estimates of the tissue optical properties. The system incorporated a laser source and a CCD c...

متن کامل

Light scattering from cells: finite-difference time-domain simulations and goniometric measurements.

We have examined the light-scattering properties of inhomogeneous biological cells through a combination of theoretical simulations and goniometric measurements. A finite-difference time-domain (FDTD) technique was used to compute intensity as a function of scattering angle for cells containing multiple organelles and spatially varying index of refraction profiles. An automated goniometer was c...

متن کامل

Comparison measurements of 0:45 radiance factor and goniometrically determined diffuse reflectance.

A comparison between the absolute gonioreflectometric scales at the Helsinki University of Technology (TKK) and the Physikalisch-Technische Bundesanstalt (PTB) has been accomplished. Six different reflection standards were measured for their 0:45 spectral radiance factor between 250 and 1650 nm in 10 nm intervals. Also, the 0:d reflectance factor between 400 and 1600 nm in 100 nm intervals was ...

متن کامل

DIFFUSE REFLECTANCE MEASUREMENTS FROM DIFFERENT SURFACES

Relative diffuse reflection measurements from the original and ground surfaces using a He-Ne laser are reported. The intensity measurements for the metallic, transparent dielectric, matte plastic surfaces and colored papers are presented. Our results indicate that among metallic surfaces tested, aluminum has the highest diffuse reflectance; while the original stainless steel surface shows the l...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007