Predictors of initial stability of orthodontic miniscrew implants.
نویسندگان
چکیده
The purpose of this retrospective study was to elucidate potential confounding factors affecting initial stability of miniscrews inserted to enhance orthodontic anchorage. Four hundred and seven miniscrews inserted in 168 patients treated by 17 orthodontic residents were analysed in a consecutive chart review. The outcome variable was the stability of the miniscrew, measured as a dichotomous variable, 0 if the miniscrew loosened during a 1 week period after insertion to the time of orthodontic force application and a value of 1 otherwise. Potential confounding variables examined were gender, age, jaw, insertion site, tissue type, length and diameter of the miniscrew, and number of previous insertions. Generalized estimating equations (GEE) methods were used to estimate the influence of each factor on stability for the correlated binary outcomes of each patient. A weighted analysis for the GEE approach was also performed for the convergence calculation of the estimation procedure due to a value of 0 in one of the cells. Crude odds ratio (cOR) and adjusted odds ratio (aOR) and their 95 per cent confidence intervals (CI) were calculated for this purpose. The overall success rate after 1 week was 93.1 per cent (379/407). The screws inserted by more experienced clinicians (more than 20 miniscrews) were found to have approximately a 3.6-fold higher success rate of initial stability compared with those inserted by less experienced clinicians after adjusting for the insertion site (aOR = 3.63, P = 0.015). The results of the present study suggest that the initial stability depends on insertion site and clinician experience.
منابع مشابه
Thread Pitch Variant in Orthodontic Mini-screws: A 3-D Finite Element Analysis
Orthodontic miniscrews are widely used as temporary anchorage devices to facilitate orthodontic movements. Miniscrew loosening is a common problem, which usually occurs during the first two weeks of treatment. Macrodesign can affect the stability of a miniscrew by changing its diameter, length, thread pitch, thread shape, tapering angle and so on. In this study, a 3-D finite element analysis wa...
متن کاملChondroitin sulphate (WF6 epitope) levels in peri-miniscrew implant crevicular fluid during orthodontic loading.
The aim of this study was to monitor changes in chondroitin sulphate (CS; WF6 epitope) levels in peri-miniscrew implant crevicular fluid (PMICF) during orthodontic loading. Ten patients (seven males and three females; aged 22.0 +/- 3.4 years), who required orthodontic treatment with extraction of all four premolar teeth, participated in the study. Twenty miniscrew implants (used as orthodontic ...
متن کاملAccurate pre-surgical determination for self-drilling miniscrew implant placement using surgical guides and cone-beam computed tomography.
Miniscrew implants have proven to be effective in providing absolute orthodontic anchorage. However, as self-drilling miniscrew implants have become more popular, a problem has emerged, i.e. root contact, which can lead to perforation and other root injuries. To avoid possible root damage, a surgical guide was fabricated and cone-beam computed tomography (CBCT) was used to incorporate guide tub...
متن کاملEvaluation of primary stability of innovated orthodontic miniscrew system (STS): An ex-vivo study
BACKGROUND Stability is determined as one of the requirements in use of Temporary Anchorage Devices (TAD) in orthodontics. Miniscrew has been a widely used Bone Anchor. Compared with mini-implant that necessitates osseointegration; mechanical retention is a determining factor for primary stability of miniscrew. Studies investigated various ways to increase primary stability. The aim of this stu...
متن کاملA Study of Success Rate of Miniscrew Implants as Temporary Anchorage Devices in Singapore
Objective. To find out the success rate of miniscrew implants in the National Dental Centre of Singapore (NDCS) and the impact of patient-related, location-related, and miniscrew implant-related factors. Materials and Methods. Two hundred and eighty-five orthodontic miniscrew implants were examined from NDCS patient records. Eleven variables were analysed to see if there is any association with...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- European journal of orthodontics
دوره 33 5 شماره
صفحات -
تاریخ انتشار 2011