Fifteen-Minute Detection of Streptococcus pyogenes in Throat Swabs by Use of a Commercially Available Point-of-Care PCR Assay.

نویسندگان

  • James R Uhl
  • Robin Patel
چکیده

Since 2002, our clinical microbiology laboratory has routinely performed Streptococcus pyogenes PCR on throat swabs using a previously described LightCycler assay which uses Roche analytespecific reagent (ASR) primers and fluorescence resonance energy transfer (FRET) probes (1). The complexity of the assay required performance in the laboratory. Recently, the United States Food and Drug Administration (FDA) cleared a Clinical Laboratory Improvement Amendments (CLIA)-waived (exempt from CLIA requirements) rapid PCR assay for detection of S. pyogenes in throat swabs, the cobas Strep A test on the Liat system (Roche Diagnostics, Indianapolis, IN), a small, automated, closed PCR instrument that processes one specimen at a time in approximately 15 min. An internal process control (IPC) monitors sample preparation and real-time PCR. Negative results do not need culture backup. An Eswab (Copan Diagnostics, Inc., Murrieta, CA) is recommended to collect the throat swab. A few drops of specimen are added to the Strep A assay tube. The single-use assay tube provides all the components needed for sample extraction and amplification; the tube is placed into the Liat instrument and results are displayed after testing is complete. We compared the cobas Liat strep A assay with our routinely used S. pyogenes LightCycler PCR assay (1). Two hundred throat swabs collected using CultureSwabs (Becton Dickinson Microbiology Systems, Cockeysville, MD) and submitted to our laboratory for S. pyogenes PCR were studied. The swabs were initially tested using the S. pyogenes LightCycler assay, as part of our routine clinical practice. Then, the Stuart’s medium in the pledget, stored at 4°C, was squeezed into a collection tube. A 100l portion of Stuart’s medium was added to an Eswab transport container with 1 ml of Amies medium for the cobas Liat group A strep test. A second 100l portion of Stuart’s medium was used for a second LightCycler PCR assay, the results of which were analyzed here. Eighty-four specimens produced positive results and 114 specimens were negative by both assays. Two specimens were only positive with the Liat assay. The sensitivity and specificity of the cobas Liat group A strep test were 100.0 and 98.3%, respectively, considering the LightCycler PCR assay as the gold standard. The positive and negative predictive values were 97.7% and 100.0%, respectively. The two specimens which were Liat strep A positive and negative with the second LightCycler PCR assay had been weakly positive by the first LightCycler PCR assay. No specimen provided an invalid result with either test. A limitation of this study is that specimens were not collected using Eswabs. We have demonstrated that the 15-min CLIA-waived PCR assay for S. pyogenes detection has performance equivalent to that of the LightCycler assay routinely used in our laboratory. The Liat strep A test is easy to use and requires virtually no training. The instrument provides an advance in PCR technology that may be advantageous to point-of-care sites, including physician offices, urgent-care locations, and hospital laboratories.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Detection of Streptococcus pyogenes by use of Illumigene group A Streptococcus assay.

The performance of the Illumigene group A Streptococcus assay was evaluated by comparing it to culture using 437 consecutive throat swabs. The Illumigene assay was also directly compared to PCR with 161 samples. This Illumigene assay is rapid and easy to perform. The assay also has high sensitivity (100%) compared to culture or PCR and high specificity (99.2%) compared to PCR. A total of 8.8% o...

متن کامل

Detection of strep throat causing bacterium directly from medical swabs by touch spray-mass spectrometry.

Strep throat causing Streptococcus pyogenes was detected in vitro and in simulated clinical samples by performing touch spray ionization-mass spectrometry. MS analysis took only seconds to reveal characteristic bacterial and human lipids. Medical swabs were used as the substrate for ambient ionization. This work constitutes the initial step in developing a non-invasive MS-based test for clinica...

متن کامل

Streptococcus pyogenes strains associated with invasive and non-invasive infections present possible links with emm types and superantigens

Objective(s): Streptococcus pyogenes, a notorious human pathogen is responsible to cause a wide range of infections varies from superficial common clinical illness to severe and life threatening infections. To our knowledge this is the first report exploring the emm types and superantigen/exotoxin gene profile of S. pyogenes from Pakistan. Materials a...

متن کامل

Comparison of Seeplex PneumoBacter aCE detection assay and in-house multiplex PCR for the identification of Streptococcus pneumoniae.

Rapid and accurate identification of Streptococcus pneumoniae is important for appropriate and prudent antimicrobial use in the treatment of lower respiratory tract infection. It is difficult to separate S. pneumoniae from commensal viridans group streptococci either by classical techniques or molecular methods. Aim of this study was to compare a commercially available multiplex PCR assay Seepl...

متن کامل

Antibiotic susceptibility of Streptococcus pyogenes isolated from throat cultures of healthy children aged between 5-15 years

Streptococcus pyogenes is one of the most important causes of bacterial pharyngitis. Asymptomatic carriage of this organism especially among schoolchildren is a common issue. Study of the prevalence and antimicrobial susceptibility pattern of the flora strains, as clinical indicators, are useful for treatment of streptococcal infections. The aim of this study was to determine the prevalence and...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 54 3  شماره 

صفحات  -

تاریخ انتشار 2016